ArticleBioengineering (Basel, Switzerland)2022
Pulsed Electric Field Ablation of Epicardial Autonomic Ganglia: Computer Analysis of Monopolar Electric Field across the Tissues Involved.
Article in Bioengineering (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 13 citations in OpenAlex.
- Endo-Epicardial Ventricular Tachycardia Ablation With Pulsed-Field Energy in an Extravascular ICD Recipient.JACC. Case reports · 2026Article
- Computational Assessment of Electrical and Thermal Effects of Epicardial Pulsed Field Ablation Adjacent to Stented Arteries.Bioengineering (Basel, Switzerland) · 2026Article
- Pulsed electric field ablation process-the effect of bifurcation stents on electric field and heat distribution.Scientific reports · 2025Article
- Effects of electric field and heat distribution due to trends in metal stent diameter in epicardial pulsed field ablation.Scientific reports · 2025Article
- Feasibility study of intravascular pulsed electric field ablation for the treatment of cardiac arrhythmias.Frontiers in physiology · 2025Article
- A New Hope for the Treatment of Atrial Fibrillation: Application of Pulsed-Field Ablation Technology.Journal of cardiovascular development and disease · 2024Review
- Pulsed Field Ablation for Atrial Fibrillation: Mechanisms, Advantages, and Limitations.Reviews in cardiovascular medicine · 2024Review
- Epicardial pulsed-field ablation-impact of electric field and heat distribution induced by coronary metallic stents.Frontiers in cardiovascular medicine · 2024Article
- Cardioneuroablation Using Epicardial Pulsed Field Ablation for the Treatment of Atrial Fibrillation.Journal of cardiovascular development and disease · 2023Review
- Article
- In Silico Modelling to Assess the Electrical and Thermal Disturbance Provoked by a Metal Intracoronary Stent during Epicardial Pulsed Electric Field Ablation.Journal of cardiovascular development and disease · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
Abstract
BACKGROUND AND
objectivesPulsed Electric Field (PEF) ablation has been proposed as a non-thermal energy to treat atrial fibrillation (AF) by epicardial ablation of ganglionated plexi (GP), which are embedded within epicardial fat. Our objective was to study the distribution of the electric field through the involved tissues (fat, GPs, myocardium and blood) during epicardial PEF ablation.
methodsA two-dimensional model was built considering different tissue layers below the ablation device which consists of an irrigated electrode. The 1000 V/cm threshold was used to estimate the 'PEF-zone'.
resultsThe PEF-zone was almost 100% circumscribed in the epicardial fat layer, with very little incidence in the myocardium. The presence of the saline on the epicardial fat causes the PEF-zone to spread laterally around the electrode from ~5 mm to ~15 mm, relatively independently of how embedded the electrode is in the saline layer. For a saline layer well spread over the tissue surface and an electrode fully embedded in the saline layer, the PEF-zone width decreases as the fat layer thickens: from ~15 mm for fat thickness of 1 and 2 mm, down to ~10 mm for fat thickness of 5 mm. The presence of a GP in the center of the fat layer hardly affects the size of the PEF-zone, but significantly alters the distribution of the electric field around the GP, resulting in progressively lower values than in the surrounding adipose tissue as the fat layer thickness increased.
conclusionsOur results suggest how some procedural (irrigation) and anatomical parameters (fat thicknesses and presence of GPs) could be relevant in terms of the size of the tissue area affected by pulsed field ablation.