ArticleBMC musculoskeletal disorders2022
Biomechanical comparison of spinal column shortening - a finite element study.
Article in BMC musculoskeletal disorders, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 10 citations in OpenAlex.
- Biomechanical Impact of Titanium Cage Tilt in the Sagittal Plane in Lumbar Total Spondylectomy: a Finite Element Analysis.Annals of biomedical engineering · 2026Article
- Unique hybrid vertebral shortening technique to treat acute traumatic thoracic spondyloptosis.Surgical neurology international · 2025Article
- Early clinical efficacy of 3D-printed artificial vertebral body in spinal reconstruction after total en bloc spondylectomy for spinal tumors.BMC musculoskeletal disorders · 2024Article
- Biomechanical study of spinal cord and nerve root in idiopathic scoliosis: based on finite element analysis.BMC musculoskeletal disorders · 2024Article
- Tethered spinal cord tension assessed via ultrasound elastography in computational and intraoperative human studies.Communications medicine · 2024Article
- Biomechanical behaviour of a novel bone cement screw in the minimally invasive treatment of Kummell's disease: a finite element study.BMC musculoskeletal disorders · 2023Article
- Comparison of anterior column reconstruction techniques after en bloc spondylectomy: a finite element study.Scientific reports · 2023Article
- Biomechanical effects of transverse connectors on total en bloc spondylectomy of the lumbar spine: a finite element analysis.Journal of orthopaedic surgery and research · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 6 institutions in 1 country.
Funding
Abstract
backgroundAt present, research on spinal shortening is mainly focused on the safe distance of spinal shortening and the mechanism of spinal cord injury, but there is no research on the biomechanical characteristics of different shortening distances. The purpose of this study was to study the biomechanical characteristics of spine and internal fixation instruments at different shortening distances by the finite element (FE) method.
methodsAn FE model of lumbar L1-S was established and referred to the previous in vitro experiments to verify the rationality of the model by verifying the Intradiscal pressure (IDP) and the range of motion (ROM) of the motion segment. Five element models of spinal shortening were designed under the safe distance of spinal shortening, and the entire L3 vertebra and both the upper and lower intervertebral discs were resected. Model A was not shortened, while models B-E were shortened by 10%, 20%, 30% and 50% of the vertebral body, respectively. Constraining the ROM of the sacrum in all directions, a 7.5 N ·m moment and 280 N follower load were applied on the L1 vertebra to simulate the motion of the lumbar vertebrae in three planes. The ROM of the operated segments, the Von Mises stress (VMS) of the screw-rod system, the VMS of the upper endplate at the interface between the titanium cage and the L4 vertebral body, and the ROM and the IDP of the adjacent segment (L5/S) were recorded and analysed.
resultsAll surgical models showed good stability at the operated segments (L1-5), with the greatest constraint in posterior extension (99.3-99.7%), followed by left-right bending (97.9-98.7%), and the least constraint in left-right rotation (84.9-86.3%) compared with the intact model. The VMS of the screw-rod system and the ROM and IDP of the distal adjacent segments of models A-E showed an increasing trend, in which the VMS of the screw-rod system of model E was the highest under flexion (172.5 MPa). The VMS of the endplate at the interface between the cage and L4 upper endplate of models A-E decreased gradually, and these trend were the most obvious in flexion, which were 3.03, 2.95, 2.83, 2.78, and 2.61 times that of the intact model, respectively.
conclusionWhen performing total vertebrae resection and correcting the spinal deformity, if the corrected spine has met our needs, the distance of spinal shortening should be minimized to prevent spinal cord injury, fracture of internal fixations and adjacent segment disease (ASD).