Trial reportJournal of clinical monitoring and computing2023
Intubation using video laryngeal mask airway SaCoVLM and laryngeal mask airway Ambu® Aura-i in anesthetized children with microtia: a randomized controlled study.
Trial report in Journal of clinical monitoring and computing, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 4 citations in OpenAlex.
- Comparison of oropharyngeal leak pressure between the SaCoVLM™ video laryngeal mask and LMA supreme in adult elective surgery patients: a prospective randomized controlled trial.BMC anesthesiology · 2025Trial
- Comparison of sacovlm™ video laryngeal mask-guided intubation and fastrach combined with flexible bronchoscopy-guided intubation -a prospective study.BMC anesthesiology · 2025Trial
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The Ambu Aura-i laryngeal mask is considered to be a device for blind intubation as well as for fiberoptic guided intubation. The novel video laryngeal airway mask SaCoVLM is a supraglottic airway device that allows intubation under direct vision. We hypothesized that success rates for device placement and tracheal intubation with the SaCoVLM would be comparable with the Ambu Aura-i mask. A prospective, randomized clinical trial was conducted from March 2021 to December 2021. One hundred and twenty patients were enrolled and randomized in the study. Direct intubation was performed with the SaCoVLM, and fiberoptic guided intubation was performed with the Ambu Aura-i mask. The primary outcome measure was the first success rate of LMA placement. Secondary outcome measures were the time from device placement and time from endotracheal intubation (as well as the time for LMA removal after successful intubation), differences in airway leak pressure, fiberoptic grade of the laryngeal view, and incidence of blood staining. The first success rate of LMA placement was similar for the two devices. There was no difference in the time for successful endotracheal intubation between the Ambu Aura-i and SaCoVLM groups (24.1 s ± 6.3 versus 25.7 s ± 2.1; p > 0.05). The time for removal was slower in the SaCoVLM group than in the Ambu Aura-i group (20.8 s ± 0.8 versus 14.7 s ± 6.1; p < 0.01). The airway leak pressure was higher in the SaCoVLM group than in the Ambu Aura-i group (27.0 s ± 1.0 versus 22.3 s ± 3.6; p < 0.01), and the incidence of blood staining was higher in the SaCoVLM group (16.7%). The SaCoVLM has an overall comparable performance to the Ambu Aura-i mask. However, the SaCoVLM is better relative to direct intubation without the assistance of a flexible intubation scope, which reduces the device's demand.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.