Evidence map›Paper›PMID 36547554›Full record

ArticleJournal of functional biomaterials2022

Corrosion Behavior and Biocompatibility of Hot-Extruded Mg-Zn-Ga-(Y) Biodegradable Alloys.

Viacheslav Bazhenov, Anna Li, Artem Iliasov, Vasily Bautin, Sofia Plegunova, Andrey Koltygin, Alexander Komissarov, Maxim Abakumov, Nikolay Redko, Kwang Seon Shin

Abstract read
In one paragraph

Article in Journal of functional biomaterials, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. An In Vivo Rat Study of Bioresorbable Mg-2Zn-2Ga Alloy Implants.Bioengineering (Basel, Switzerland) · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Viacheslav BazhenovCasting Department, National University of Science and Technology "MISiS", Leninskiy pr. 4, 119049 Moscow, Russia.ORCID 0000-0003-3214-1935
Anna LiLaboratory of Hybrid Nanostructured Materials, National University of Science and Technology "MISiS", Leninskiy pr. 4, 119049 Moscow, Russia.
Artem IliasovLaboratory of Biomedical Nanomaterials, National University of Science and Technology "MISiS", Leninskiy pr. 4, 119049 Moscow, Russia.
Vasily BautinDepartment of Metallurgy Steel, New Production Technologies and Protection of Metals, National University of Science and Technology "MISiS", Leninskiy pr. 4, 119049 Moscow, Russia.ORCID 0000-0003-2842-1491
Sofia PlegunovaLaboratory of Biomedical Nanomaterials, National University of Science and Technology "MISiS", Leninskiy pr. 4, 119049 Moscow, Russia.
Andrey KoltyginCasting Department, National University of Science and Technology "MISiS", Leninskiy pr. 4, 119049 Moscow, Russia.ORCID 0000-0002-8376-0480
Alexander KomissarovLaboratory of Hybrid Nanostructured Materials, National University of Science and Technology "MISiS", Leninskiy pr. 4, 119049 Moscow, Russia.ORCID 0000-0001-5125-9870
Maxim AbakumovLaboratory of Biomedical Nanomaterials, National University of Science and Technology "MISiS", Leninskiy pr. 4, 119049 Moscow, Russia.ORCID 0000-0003-2622-9201
Nikolay RedkoLaboratory of Medical Bioresorption and Bioresistance, Moscow State University of Medicine and Dentistry, Delegatskaya 20/1, 127473 Moscow, Russia.ORCID 0000-0001-7807-9351
Kwang Seon ShinLaboratory of Medical Bioresorption and Bioresistance, Moscow State University of Medicine and Dentistry, Delegatskaya 20/1, 127473 Moscow, Russia.ORCID 0000-0002-2902-0027

Funding

Ministry of Science and Higher Education of the Russian Federation 075-15-2022-1133
6 · The paper itself

Abstract

Fixation screws and other temporary magnesium alloy fixation devices are used in orthopedic practice because of their biodegradability, biocompatibility and acceptable biodegradation rates. The substitution of dissolving implant by tissues during the healing process is one of the main requirements for biodegradable implants. Previously, clinical tests showed the effectiveness of Ga ions on bone tissue regeneration. This work is the first systematic study on the corrosion rate and biocompatibility of Mg-Zn-Ga-(Y) alloys prepared by hot extrusion, where Ga is an additional major alloying element, efficient as a bone-resorption inhibitor. Most investigated alloys have a low corrosion rate in Hanks' solution close to ~0.2 mm/year. No cytotoxic effects of Mg-2Zn-2Ga (wt.%) alloy on MG63 cells were observed. Thus, considering the high corrosion resistance and good biocompatibility, the Mg-2Zn-2Ga alloy is possible for applications in osteosynthesis implants with improved bone tissue regeneration ability.

Indexed as

biomaterialscorrosion resistancecytotoxicitygalliumHanks’ solutionmagnesium

Identifiers

PMID36547554
PMCPMC9784916

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.