ArticleJournal of cardiovascular development and disease2022

In Silico Modelling to Assess the Electrical and Thermal Disturbance Provoked by a Metal Intracoronary Stent during Epicardial Pulsed Electric Field Ablation.

Ana González-Suárez, Juan J Pérez, Barry O'Brien, Adnan Elahi

Open access · goldAbstract read
In one paragraph

Article in Journal of cardiovascular development and disease, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
3.0field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 18 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Cardiac selectivity in pulsed field ablation.Current opinion in cardiology · 2025
    Review
  9. Article
  10. Article
  11. Review
  12. Review
  13. Review
  14. Article
  15. Article
  16. Article
  17. Review
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Ana González-SuárezSchool of Engineering, University of Galway, H91 TK33 Galway, Ireland.ORCID 0000-0002-1813-4176
Juan J PérezBioMIT, Department of Electronic Engineering, Universitat Politècnica de València, 46022 Valencia, Spain.ORCID 0000-0001-8486-8699
Barry O'BrienAtriAN Medical Limited, Unit 204, University of Galway Business Innovation Centre, Upper Newcastle, H91 W60E Galway, Ireland.
Adnan ElahiSchool of Engineering, University of Galway, H91 TK33 Galway, Ireland.ORCID 0000-0003-0988-5776
Ollscoil na Gaillimhe – University of Galway · IEUniversitat Politècnica de València · ES

Funding

Government of Ireland DT20180123Spanish MCIN/AEI/ 10.13039/501100011033 RTI2018-094357-B-C21
6 · The paper itself

Abstract

Background: Pulsed Electric Field (PEF) ablation has been recently proposed to ablate cardiac ganglionic plexi (GP) aimed to treat atrial fibrillation. The effect of metal intracoronary stents in the vicinity of the ablation electrode has not been yet assessed. Methods: A 2D numerical model was developed accounting for the different tissues involved in PEF ablation with an irrigated ablation device. A coronary artery (with and without a metal intracoronary stent) was considered near the ablation source (0.25 and 1 mm separation). The 1000 V/cm threshold was used to estimate the ‘PEF-zone’. Results: The presence of the coronary artery (with or without stent) distorts the E-field distribution, creating hot spots (higher E-field values) in the front and rear of the artery, and cold spots (lower E-field values) on the sides of the artery. The value of the E-field inside the coronary artery is very low (~200 V/cm), and almost zero with a metal stent. Despite this distortion, the PEF-zone contour is almost identical with and without artery/stent, remaining almost completely confined within the fat layer in any case. The mentioned hot spots of E-field translate into a moderate temperature increase (<48 °C) in the area between the artery and electrode. These thermal side effects are similar for pulse intervals of 10 and 100 μs. Conclusions: The presence of a metal intracoronary stent near the ablation device during PEF ablation simply ‘amplifies’ the E-field distortion already caused by the presence of the vessel. This distortion may involve moderate heating (<48 °C) in the tissue between the artery and ablation electrode without associated thermal damage.

Indexed as

cardiac arrhythmiacomputer modellingcoronary arteryepicardial ablationmetal stentpulsed field ablation

Identifiers

PMID36547455
PMCPMC9784210
OpenAlexW4311398912

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.