In Silico Modelling to Assess the Electrical and Thermal Disturbance Provoked by a Metal Intracoronary Stent during Epicardial Pulsed Electric Field Ablation.
Article in Journal of cardiovascular development and disease, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
18 citing papers in PubMed, 18 citations in OpenAlex.
- Unexpected Lattice-Tip Catheter Overheating During Pulsed Electric Field Ablation Near Metal Implants.JACC. Case reports · 2026Article
- New Energy, Old Lessons: The Evolving Safety Profile of Pulsed Field Ablation.JACC. Case reports · 2026Article
- Computational Assessment of Electrical and Thermal Effects of Epicardial Pulsed Field Ablation Adjacent to Stented Arteries.Bioengineering (Basel, Switzerland) · 2026Article
- Numerical analysis of low-frequency electromagnetic field effects from three-phase transformer on coronary stents and cardiac tissues.PloS one · 2026Article
- Influence of Coronary Flow and Left Ventricular Outflow Tract Velocity on LDL Accumulation and Calcification in Aortic Valve Leaflets.Biomechanics (Basel, Switzerland) · 2025Article
- Pulsed electric field ablation process-the effect of bifurcation stents on electric field and heat distribution.Scientific reports · 2025Article
- Effects of electric field and heat distribution due to trends in metal stent diameter in epicardial pulsed field ablation.Scientific reports · 2025Article
- Cardiac selectivity in pulsed field ablation.Current opinion in cardiology · 2025Review
- Pulsed electric field ablation process-a study of the effect of different shapes (materials) of metal stents on the ablation effect.Frontiers in cardiovascular medicine · 2025Article
- Feasibility study of intravascular pulsed electric field ablation for the treatment of cardiac arrhythmias.Frontiers in physiology · 2025Article
- A New Hope for the Treatment of Atrial Fibrillation: Application of Pulsed-Field Ablation Technology.Journal of cardiovascular development and disease · 2024Review
- Mechanisms of action behind the protective effects of proactive esophageal cooling during radiofrequency catheter ablation in the left atrium.Heart rhythm O2 · 2024Review
- Pulsed Field Ablation for Atrial Fibrillation: Mechanisms, Advantages, and Limitations.Reviews in cardiovascular medicine · 2024Review
- Epicardial pulsed-field ablation-impact of electric field and heat distribution induced by coronary metallic stents.Frontiers in cardiovascular medicine · 2024Article
- Cardiac blood vessels and irreversible electroporation: findings from pulsed field ablation.Vessel plus · 2024Article
- Epicardial Pulsed Field Ablation of Ganglionated Plexi: Computational and Pre-Clinical Evaluation of a Bipolar Sub-Xiphoid Catheter for the Treatment of Atrial Fibrillation.Bioengineering (Basel, Switzerland) · 2023Article
- Cardioneuroablation Using Epicardial Pulsed Field Ablation for the Treatment of Atrial Fibrillation.Journal of cardiovascular development and disease · 2023Review
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 2 countries.
Funding
Abstract
Background: Pulsed Electric Field (PEF) ablation has been recently proposed to ablate cardiac ganglionic plexi (GP) aimed to treat atrial fibrillation. The effect of metal intracoronary stents in the vicinity of the ablation electrode has not been yet assessed. Methods: A 2D numerical model was developed accounting for the different tissues involved in PEF ablation with an irrigated ablation device. A coronary artery (with and without a metal intracoronary stent) was considered near the ablation source (0.25 and 1 mm separation). The 1000 V/cm threshold was used to estimate the ‘PEF-zone’. Results: The presence of the coronary artery (with or without stent) distorts the E-field distribution, creating hot spots (higher E-field values) in the front and rear of the artery, and cold spots (lower E-field values) on the sides of the artery. The value of the E-field inside the coronary artery is very low (~200 V/cm), and almost zero with a metal stent. Despite this distortion, the PEF-zone contour is almost identical with and without artery/stent, remaining almost completely confined within the fat layer in any case. The mentioned hot spots of E-field translate into a moderate temperature increase (<48 °C) in the area between the artery and electrode. These thermal side effects are similar for pulse intervals of 10 and 100 μs. Conclusions: The presence of a metal intracoronary stent near the ablation device during PEF ablation simply ‘amplifies’ the E-field distortion already caused by the presence of the vessel. This distortion may involve moderate heating (<48 °C) in the tissue between the artery and ablation electrode without associated thermal damage.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.