Evidence map›Paper›PMID 36545853›Full record

ArticleZhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery2022

[Effectiveness analysis of proximal humerus internal locking system plate combined with rotator cuff reinforcement suture in treatment of Neer type Ⅳ proximal humerus fracture].

Jinquan Ma, Yingchen Ni, Minhao Chen, Weidong Zhang, Hua Xu, Youhua Wang

Open access · greenAbstract readEnglish Abstract
In one paragraph

Article in Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Jinquan MaDepartment of Orthopedics, Affiliated Hospital of Nantong University, Nantong Jiangsu, 226001, P. R. China.
Yingchen NiDepartment of Orthopedics, Affiliated Hospital of Nantong University, Nantong Jiangsu, 226001, P. R. China.
Minhao ChenDepartment of Orthopedics, Affiliated Hospital of Nantong University, Nantong Jiangsu, 226001, P. R. China.
Weidong ZhangDepartment of Orthopedics, Affiliated Hospital of Nantong University, Nantong Jiangsu, 226001, P. R. China.
Hua XuDepartment of Orthopedics, Affiliated Hospital of Nantong University, Nantong Jiangsu, 226001, P. R. China.
Youhua WangDepartment of Orthopedics, Affiliated Hospital of Nantong University, Nantong Jiangsu, 226001, P. R. China.
Nantong University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: To investigate the effectiveness of proximal humerus internal locking system (PHILOS) plate combined with rotator cuff reinforcement suture in the treatment of Neer type Ⅳ proximal humerus fracture. Methods: The clinical data of 48 patients with proximal humeral fractures admitted between January 2016 and December 2020 were retrospectively analyzed, including 18 males and 30 females. The age ranged from 28 to 69 years (mean, 56.3 years). The causes of injury included falling in 39 cases and traffic accident in 9 cases. The time from injury to operation was 2-5 days (mean, 2.8 days). All of them were Neer type Ⅳ proximal humerus fractures, including 11 patients with dislocation. All patients underwent internal fixation with a PHILOS plate after anatomical reduction of the greater nodule, and the rotator cuff was sutured to the plate to reinforce fixation. The operation time was recorded, the wound healing, fracture healing, and complications were observed. The visual analogue scale (VAS) score, Constant-Murley shoulder score, University of California Los Angeles (UCLA) score, and American Shoulder and Elbow Surgeons (ASES) score were used to evaluate shoulder function before operation, at 3 months after operation, and at last follow-up. Results: The operation time ranged from 65 to 90 minutes (mean, 76.9 minutes). All incisions healed by first intention. All patients were followed up 9-16 months (mean, 12 months). Fracture reduction was good and all fractures healed, the healing time was 2-6 months (mean, 4.6 months). There was no complication such as subacromial impingement, fracture redisplacement, and screw removal during follow-up. One patient had humeral head necrosis, but the basic function of the shoulder joint was acceptable, the symptoms were mild, and no treatment was performed. At 3 months after operation, the upper limb function of the patients basically recovered. The VAS score, Constant-Murley score, UCLA score, and ASES score significantly improved at 3 months after operation and at last follow-up when compared with preoperative, and further improved at last follow-up than at 3 months after operation ( Conclusion: PHILOS plate combined with rotator cuff reinforcement suture in the treatment of Neer type Ⅳ proximal humerus fracture has the advantages of promoting early postoperative rehabilitation exercise, improving postoperative function of shoulder joint, and reducing complications.

Indexed as

Humeral FracturesShoulder FracturesAdultAgedBone PlatesFemaleFracture Fixation, InternalHumansHumeral HeadHumerusMaleMiddle AgedRetrospective StudiesRotator CuffShoulderSuturesgreater tuberosity of humerusinternal fixationProximal humeral fracturerotator cuff

Identifiers

PMID36545853
PMCPMC9763062
OpenAlexW4312113530

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.