Evidence map›Paper›PMID 36545261›Full record

ArticleOphthalmology science2023

Transient Increase of Flicker Electroretinography Amplitudes after Cataract Surgery: Association with Postoperative Inflammation.

Kumiko Kato, Ryunosuke Nagashima, Hisashi Matsubara, Kengo Ikesugi, Hideyuki Tsukitome, Yoshitsugu Matsui, Takayasu Nunome, Masahiko Sugimoto, Daphne L McCulloch, Mineo Kondo

Abstract read
In one paragraph

Article in Ophthalmology science, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Article
  2. Article
  3. Intra- and inter-examiner reliability of ERGs recorded with two types of skin electrodes.Documenta ophthalmologica. Advances in ophthalmology · 2026
    Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Review
  10. Review
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Kumiko KatoDepartment of Ophthalmology, Mie University Graduate School of Medicine, Tsu, Japan.
Ryunosuke NagashimaDepartment of Ophthalmology, Mie University Graduate School of Medicine, Tsu, Japan.
Hisashi MatsubaraDepartment of Ophthalmology, Mie University Graduate School of Medicine, Tsu, Japan.
Kengo IkesugiDepartment of Ophthalmology, Mie University Graduate School of Medicine, Tsu, Japan.
Hideyuki TsukitomeDepartment of Ophthalmology, Mie University Graduate School of Medicine, Tsu, Japan.
Yoshitsugu MatsuiDepartment of Ophthalmology, Mie University Graduate School of Medicine, Tsu, Japan.
Takayasu NunomeDepartment of Ophthalmology, Mie University Graduate School of Medicine, Tsu, Japan.
Masahiko SugimotoDepartment of Ophthalmology, Mie University Graduate School of Medicine, Tsu, Japan.
Daphne L McCullochSchool of Optometry and Vision Science, University of Waterloo, Waterloo, Canada.
Mineo KondoDepartment of Ophthalmology, Mie University Graduate School of Medicine, Tsu, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To determine the characteristics and cause of the increase in the amplitude of flicker electroretinography (ERG) after cataract surgery. Design: Prospective, observational clinical study. Participants: Thirty patients who underwent cataract surgery. Methods: Flicker ERGs were recorded with the RETeval system without mydriasis. The central macular thickness (CMT) was measured by OCT and the aqueous flare value (AFV) by laser flare-cell photometry. These examinations were performed before surgery and 1 day, 1 week, 1 month, 2 months, and 3 months after surgery. Linear regression analysis through the origin was used to compare the correlations between the relative changes in flicker ERG amplitudes and the changes in the CMT and AFV at different times after the surgery. Main Outcome Measures: The amplitude of flicker ERGs, CMT, and AFV. Results: The mean amplitude of flicker ERGs increased significantly by 31% at 1 week after surgery ( Conclusions: These results suggest that the increase in the amplitude of flicker ERGs after cataract surgery is a transient phenomenon that has a peak at 1 week after surgery. The increase of flicker ERG amplitude was associated with measures that are frequently used to evaluate postoperative inflammation. Financial Disclosures: Proprietary or commercial disclosure may be found after the references.

Indexed as

AFV, aqueous flare valueAqueous flare valueCataract surgeryCentral macular thicknessCMT, central macular thicknessElectroretinographyERG, electroretinographyInflammationNO, nitric oxide

Identifiers

PMID36545261
PMCPMC9762194

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.