Evidence map›Paper›PMID 36543227›Full record

ArticleMagnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine2024

Simultaneous Arterial and Venous Imaging Using 3D Quantitative Parameter Mapping.

Tomoki Amemiya, Suguru Yokosawa, Yo Taniguchi, Ryota Sato, Yoshihisa Soutome, Hisaaki Ochi, Toru Shirai

Open access · diamondAbstract read
In one paragraph

Article in Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.3field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Tomoki AmemiyaInnovative Technology Laboratory, FUJIFILM Healthcare Corporation.
Suguru YokosawaInnovative Technology Laboratory, FUJIFILM Healthcare Corporation.
Yo TaniguchiInnovative Technology Laboratory, FUJIFILM Healthcare Corporation.
Ryota SatoInnovative Technology Laboratory, FUJIFILM Healthcare Corporation.
Yoshihisa SoutomeInnovative Technology Laboratory, FUJIFILM Healthcare Corporation.
Hisaaki OchiInnovative Technology Laboratory, FUJIFILM Healthcare Corporation.
Toru ShiraiInnovative Technology Laboratory, FUJIFILM Healthcare Corporation.
Fujifilm (Japan) · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo increase the number of images that can be acquired in MR examinations using quantitative parameters, we developed a method for obtaining arterial and venous images with mapping of proton density (PD), RF inhomogeneity (B1), longitudinal relaxation time (T1), apparent transverse relaxation time (T2*), and magnetic susceptibility through calculation, all with the same spatial resolution.

methodsThe proposed method uses partially RF-spoiled gradient echo sequences to obtain 3D images of a subject with multiple scan parameters. The PD, B1, T1, T2*, and magnetic susceptibility maps are estimated using the quantification method we previously developed. Arterial images are obtained by adding images using optimized weights to emphasize the arteries. A morphology filter is used to obtain venous images from the magnetic susceptibility maps. For evaluation, images obtained from four out of five healthy volunteers were used to optimize the weights used in the arterial-image calculation, and the optimized weights were applied to the images from the fifth volunteer to obtain an arterial image. Arterial images of the five volunteers were calculated using the leave-one-out method, and the contrast between the arterial and background regions defined using the reference time-of-flight (TOF) method was evaluated using the area under the receiver operation characteristic curve (AUC). The contrast between venous and background regions defined by a reference quantitative susceptibility mapping (QSM) method was also evaluated for the venous image.

resultsThe AUC to discriminate blood vessels and background using the proposed method was 0.905 for the arterial image and 0.920 for the venous image.

conclusionThe results indicate that the arterial images and venous images have high signal intensity at the same region as determined from the reference TOF and QSM methods, demonstrating the possibility of acquiring vasculature images with quantitative parameter mapping through calculation in an integrated manner.

Indexed as

BrainBrain MappingArteriesHumansImage Processing, Computer-AssistedMagnetic Resonance Imagingarterymulti-parameter mappingrelaxation timesusceptibilityvein

Identifiers

PMID36543227
PMCPMC10838721
OpenAlexW4312093605

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.