Evidence map›Paper›PMID 36543205›Full record

ArticleNeurologia medico-chirurgica2023

Pipeline Flex with Shield Technology Placement for Small- and Medium-sized Aneurysms Achieves Early Complete Occlusion.

Sho Arai, Takashi Fujii, Kohsuke Teranishi, Senshu Nonaka, Takayuki Kitamura, Yumiko Mitome-Mishima, Akihide Kondo, Hidenori Oishi

Open access · goldAbstract read
In one paragraph

Article in Neurologia medico-chirurgica, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
1.5field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it, 15 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Biomimetic polymers with phosphorylcholine groups as biomaterials for medical devices.Proceedings of the Japan Academy. Series B, Physical and biological sciences · 2024
    Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Sho AraiDepartment of Neurosurgery, Graduate School of Medicine, Juntendo University.
Takashi FujiiDepartment of Neuroendovascular Therapy, Graduate School of Medicine, Juntendo University.
Kohsuke TeranishiDepartment of Neurosurgery, Graduate School of Medicine, Juntendo University.
Senshu NonakaDepartment of Neurosurgery, Graduate School of Medicine, Juntendo University.
Takayuki KitamuraDepartment of Neurosurgery, Graduate School of Medicine, Juntendo University.
Yumiko Mitome-MishimaDepartment of Neurosurgery, Graduate School of Medicine, Juntendo University.
Akihide KondoDepartment of Neurosurgery, Graduate School of Medicine, Juntendo University.
Hidenori OishiDepartment of Neurosurgery, Graduate School of Medicine, Juntendo University.
Juntendo University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The flow diverter has been shown to be a safe and effective device for large cerebral aneurysms in the proximal internal carotid artery (ICA). Recently, its indication has been expanded to small- and medium-sized cerebral aneurysms in the distal segment of the ICA. In this study, we report a single-center, retrospective investigation of the safety and efficacy of the Pipeline Flex device to treat these aneurysms. Of the patients who underwent Pipeline implantation for small- and medium-sized ICA aneurysms (≤12 mm) at our hospital between July 2013 and October 2021, 102 patients with 104 aneurysms were included in this study. The mean age of the patients was 57.7 ± 12.1 years, and 94 (90.4%) were female. The mean aneurysmal dome diameter was 9.2 ± 2.3 mm, the mean neck diameter was 5.3 ± 1.6 mm, and the mean dome-to-neck ratio was 1.8 ± 0.5. Twenty-five patients (24.0%) had incorporated vessels from the aneurysm. Complete occlusion of the aneurysms was obtained in 96 patients (92.3%). There were no cases of parent artery stenosis or major stroke after the procedure. Absence of incorporated vessel from the aneurysm dome and adjunctive coil embolization are statistically significant factors indicating complete occlusion in multivariate analysis. The time to complete occlusion was determined earlier with the use of the Pipeline Shield (p = 0.0386) and with adjunctive coils (p = 0.0025). We showed that Pipeline implantation for small- and medium-sized aneurysms was safe and highly effective.

Indexed as

Embolization, TherapeuticIntracranial AneurysmAgedCerebral AngiographyFemaleHumansMaleMiddle AgedProspective StudiesRetrospective StudiesStentsTreatment Outcomeflow diverterPipeline Flex with Shield technologySmall- and medium-sized aneurysm

Identifiers

PMID36543205
PMCPMC9995145
OpenAlexW4312095239

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.