Evidence map›Paper›PMID 36542378›Full record

SynthesisJAMA network open2022

Safety and Success Rates of Excimer Laser Sheath-Assisted Retrieval of Embedded Inferior Vena Cava Filters.

Kush R Desai, John Kaufman, Parker Truong, Jonathan D Lindquist, Osman Ahmed, Siobhan M Flanagan, Mark J Garcia, Rashmi Ram, Yu-Rong Gao, Robert J Lewandowski and 1 more

Abstract readMeta-Analysis
In one paragraph

Synthesis in JAMA network open, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Inferior Vena Cava Filter Retrieval: Simple to Complex.Cardiovascular and interventional radiology · 2024
    Review
  4. Review
  5. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

11 authors.

Kush R DesaiDepartment of Radiology, Northwestern University, Chicago, Illinois.
John KaufmanDepartment of Interventional Radiology, Oregon Health & Science University, Portland.
Parker TruongDepartment of Interventional Radiology, Oklahoma Heart Hospital, Oklahoma City.
Jonathan D LindquistDivision of Vascular and Interventional Radiology, Department of Radiology, University of Colorado Anschutz Medical Center, Aurora.
Osman AhmedDepartment of Radiology, The University of Chicago, Chicago, Illinois.
Siobhan M FlanaganDivision of Vascular and Interventional Radiology, Department of Radiology, University of Minnesota Medical Center, Minneapolis.
Mark J GarciaEndoVascular Consultants, Wilmington, Delaware.
Rashmi RamDepartment of Clinical & Medical Affairs, Philips North America LLC, Cambridge, Massachusetts.
Yu-Rong GaoDepartment of Clinical & Medical Affairs, Philips North America LLC, Cambridge, Massachusetts.
Robert J LewandowskiDepartment of Radiology, Northwestern University, Chicago, Illinois.
Robert K RyuDepartment of Radiology, Keck School of Medicine, University of Southern California, Los Angeles.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Importance: Despite historically high rates of use, most inferior vena cava (IVC) filters are not retrieved. The US Food and Drug Administration safety communications recommended retrieval when the IVC filter is no longer indicated out of concern for filter-related complications. However, failure rates are high when using standard techniques for retrieval of long-dwelling filters, and until recently, there have been no devices approved for retrieval of embedded IVC filters. Objective: To evaluate the safety and success of excimer laser sheath-assisted retrieval of embedded IVC filters. Design, Setting, and Participants: A retrospective, multicenter, clinical cohort study of excimer laser sheath-assisted IVC filter retrievals from 7 US sites was conducted between March 1, 2012, and February 28, 2021, among 265 patients who underwent IVC filter retrieval using the laser. Patients were substratified between a high-volume single center and a multicenter data set. A blinded physician committee adjudicated reported complications and their association with use of the laser. Exposures: Retrieval of IVC filters using excimer laser sheath. Main Outcomes and Measures: The primary safety end point was device-related major complication rate (Society of Interventional Radiology categories C to F, which included any adverse event associated with morbidity or disability that increases the level of care, results in hospital admission, or substantially lengthens the hospital stay). The primary success end point was technical success of IVC filter retrieval. The primary end points were compared with literature-derived, meta-analysis-suggested target performance goals. Results: The single-center experience included 139 participants (mean [SD] age, 52 [16] years; 78 female participants [56.1%]), and the multicenter experience included 126 participants (mean [SD] age, 52 [16] years; 75 female participants [59.5%]). The device-related major complication rate was 2.9% (4 of 139; 95% CI, 0.8%-7.2%; P = .001) for the single-center experience and 4.0% (5 of 126; 95% CI, 1.3%-9.0%; P = .01) for the multicenter experience, both of which were significantly lower than the primary safety performance goal (10%). No major complications were considered to be definitively associated with use of the laser. The technical success rate was 95.7% (133 of 139; 95% CI, 90.8%-98.4%; P = .007) for the single-center experience and 95.2% (120 of 126; 95% CI, 89.9%-98.2%; P = .02) for the multicenter experience, both of which were significantly higher than the primary performance goal (89.4%). Conclusions and Relevance: This cohort study demonstrated high technical success and low complication rates of excimer laser sheath-assisted retrieval of embedded IVC filters in centers with variable case volume and experience, which suggests a wide applicability of the technique with proper training. The excimer laser sheath offers physicians a valuable tool for retrieval of challenging embedded IVC filters.

Indexed as

Lasers, ExcimerVena Cava FiltersCohort StudiesDevice RemovalFemaleHumansMiddle AgedMulticenter Studies as TopicRetrospective Studies

Identifiers

PMID36542378
PMCPMC9856719

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.