SynthesisJAMA network open2022
Safety and Success Rates of Excimer Laser Sheath-Assisted Retrieval of Embedded Inferior Vena Cava Filters.
Synthesis in JAMA network open, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Balloon-assisted radial release for retrieval of a surgically suture-fixed inferior vena cava filter: a case report.Thrombosis journal · 2026Article
- Retrieval of an IVCF retained for over 6 years via femoral venous approach using a large-bore sheath: a case report and literature review.Frontiers in cardiovascular medicine · 2025Article
- Inferior Vena Cava Filter Retrieval: Simple to Complex.Cardiovascular and interventional radiology · 2024Review
- Inferior Vena Cava Filters: A Clinical Review and Future Perspectives.Journal of clinical medicine · 2024Review
- Laser-assisted permanent greenfield filter removal with ileocaval stent reconstruction following filter thrombosis, a case report.Radiology case reports · 2023Article
Corrections and comments
- Commented on byBeyond the2023
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Importance: Despite historically high rates of use, most inferior vena cava (IVC) filters are not retrieved. The US Food and Drug Administration safety communications recommended retrieval when the IVC filter is no longer indicated out of concern for filter-related complications. However, failure rates are high when using standard techniques for retrieval of long-dwelling filters, and until recently, there have been no devices approved for retrieval of embedded IVC filters. Objective: To evaluate the safety and success of excimer laser sheath-assisted retrieval of embedded IVC filters. Design, Setting, and Participants: A retrospective, multicenter, clinical cohort study of excimer laser sheath-assisted IVC filter retrievals from 7 US sites was conducted between March 1, 2012, and February 28, 2021, among 265 patients who underwent IVC filter retrieval using the laser. Patients were substratified between a high-volume single center and a multicenter data set. A blinded physician committee adjudicated reported complications and their association with use of the laser. Exposures: Retrieval of IVC filters using excimer laser sheath. Main Outcomes and Measures: The primary safety end point was device-related major complication rate (Society of Interventional Radiology categories C to F, which included any adverse event associated with morbidity or disability that increases the level of care, results in hospital admission, or substantially lengthens the hospital stay). The primary success end point was technical success of IVC filter retrieval. The primary end points were compared with literature-derived, meta-analysis-suggested target performance goals. Results: The single-center experience included 139 participants (mean [SD] age, 52 [16] years; 78 female participants [56.1%]), and the multicenter experience included 126 participants (mean [SD] age, 52 [16] years; 75 female participants [59.5%]). The device-related major complication rate was 2.9% (4 of 139; 95% CI, 0.8%-7.2%; P = .001) for the single-center experience and 4.0% (5 of 126; 95% CI, 1.3%-9.0%; P = .01) for the multicenter experience, both of which were significantly lower than the primary safety performance goal (10%). No major complications were considered to be definitively associated with use of the laser. The technical success rate was 95.7% (133 of 139; 95% CI, 90.8%-98.4%; P = .007) for the single-center experience and 95.2% (120 of 126; 95% CI, 89.9%-98.2%; P = .02) for the multicenter experience, both of which were significantly higher than the primary performance goal (89.4%). Conclusions and Relevance: This cohort study demonstrated high technical success and low complication rates of excimer laser sheath-assisted retrieval of embedded IVC filters in centers with variable case volume and experience, which suggests a wide applicability of the technique with proper training. The excimer laser sheath offers physicians a valuable tool for retrieval of challenging embedded IVC filters.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.