ArticleLangmuir : the ACS journal of surfaces and colloids2023
Controlled Transport of Individual Microparticles Using Dielectrophoresis.
Article in Langmuir : the ACS journal of surfaces and colloids, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed, 25 citations in OpenAlex.
- Theoretical and Experimental Studies on AC Electric Field Induced Droplet Deformation in a Microchannel.Micromachines · 2026Article
- Thermal Recovery of Damaged Hydrophobic Coatings in EWOD Devices Using an Integrated Mesh-Patterned Heater.Micromachines · 2026Article
- Integrated electrical modeling of circulating tumor cells for enhanced dielectrophoretic trapping and electroporation.Scientific reports · 2026Article
- Diffusiophoresis of a Weakly Charged Dielectric Fluid Droplet in a Cylindrical Pore.Micromachines · 2025Article
- Design and Implementation of a High-Throughput Digital Microfluidic System Based on Optimized YOLOv8 Object Detection.Micromachines · 2025Article
- Development of a Tool for Verifying Leakage Detection in Microfluidic Systems.Micromachines · 2025Article
- Parallelization of Curved Inertial Microfluidic Channels to Increase the Throughput of Simultaneous Microparticle Separation and Washing.Micromachines · 2024Article
- Recent Advances in Research from Nanoparticle to Nano-Assembly: A Review.Nanomaterials (Basel, Switzerland) · 2024Review
- Fabrication of Two-Layer Microfluidic Devices with Porous Electrodes Using Printed Sacrificial Layers.Micromachines · 2024Article
- Impedance matching in optically induced dielectrophoresis: Effect of medium conductivity on trapping force.Applied physics letters · 2024Article
- Integrated Microfluidics for Single-Cell Separation and On-Chip Analysis: Novel Applications and Recent Advances.Small science · 2024Article
- Beyond two dimensions: Exploring 3D dielectrophoresis for microparticle control using carbon electrodes.PloS one · 2024Article
- Design and Fabrication of a 3D-Printed Microfluidic Immunoarray for Ultrasensitive Multiplexed Protein Detection.Micromachines · 2023Article
- Migration Study of Dielectrophoretically Manipulated Red Blood Cells in Tapered Aluminium Microelectrode Array: A Pilot Study.Micromachines · 2023Article
- Enhancing the Accuracy of Measuring DEP Force Applied on Cells by Considering the Friction Effect.Biosensors · 2023Article
- Conduction Conditions for Self-Healing of Metal Interconnect Using Copper Microparticles Dispersed with Silicone Oil.Micromachines · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
Abstract
A dielectrophoretic device employing a planar array of microelectrodes is designed for controlled transport of individual microparticles. By exciting the electrodes in sequence, a moving dielectrophoretic force is created that can drag a particle across the electrodes in a straight line. The electrode shapes are designed to counter any lateral drift of the trapped particle during transport. This facilitates single particle transport by creating a narrow two-dimensional corridor for the moving dielectrophoretic force to operate on. The design and analysis processes are discussed in detail. Numerical simulations are performed to calculate the electromagnetic field distribution and the generated dielectrophoretic force near the electrodes. The Langevin equation is used for analyzing the trajectory of a microparticle under the influence of the external forces. The simulations show how the designed electrode geometry produces the necessary lateral confinement required for successful particle transport. Finally, experimental results are presented showing controlled bidirectional linear transport of single polystyrene beads of radius 10 and 5 μm for a distances 840 and 1100 μm, respectively. The capabilities of the proposed platform make it suitable for micro total analysis systems (μTAS) and lab-on-a-chip (LOC) applications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.