ArticleScientific reports2022
Blood glucose sensing by back gated transistor strips sensitized by CuO hollow spheres and rGO.
Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 26 citations in OpenAlex.
- Advanced smartwatch for noninvasive sweat biomarker monitoring using a wearable FET biosensor array with Ag nanowire cross-linked MoSScientific reports · 2026Article
- Wearable MXene-enhanced organic Bio-FET paper patch for glucose detection in sweat with pH and temperature calibration.Scientific reports · 2025Article
- Integrated electronic/fluidic microneedle system for glucose sensing and insulin delivery.Theranostics · 2024Article
- Development of a portable smart Glucometer with two electrode bio-electronic test strip patch based on Cu/Au/rGO/PEDOT:PSS.Scientific reports · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In this work, a highly sensitive flexible glucose sensor based on a field effect transistor (FET) has been fabricated. It is shown that the proposed flexible transistor can be used as new non-enzymatic blood glucose test strips. CuO hollow-spheres decorated with reduced graphene oxide have been synthesized using the hydrothermal method. The shells of the hollow micro-spheres are formed by nanostructures. The synthesized nanostructured hollow micro-spheres (rGO/CuO-NHS) are deposited on a flexible PET substrate between interdigitated electrodes as the channel of a back gate transistor. The channel concentration and the FET bias are optimized so that the sensor exhibits extremely low limit of detection and high sensitivity. The combination of selective porous CuO hollow spheres and the high surface to volume ratio of their nanostructured shells with the high mobility and high conductivity rGO led to faster and higher charge-transfer capability and superior electro-catalyst activity for glucose oxidation. The glucose-dependent electrical responses of the sensor is measured in both resistive and transistor action modes. The amplification of the current by the induced electric field of the gate in the proposed FET-based biosensor provides advantages such as higher sensitivity and lower limit of detection compared to the resistive sensor. The flexible glucose sensor has a sensitivity of 600 μA μM
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.