Evidence map›Paper›PMID 36533561›Full record

ArticleThe British journal of radiology2023

Occupational and patient doses for interventional radiology integrated into a dose management system.

Eliseo Vano, José M Fernandez-Soto, José I Ten, Roberto M Sanchez Casanueva

Abstract read
In one paragraph

Article in The British journal of radiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Exposure to ionizing radiation of medical staff performing vascular and interventional radiology procedures.International journal of occupational medicine and environmental health · 2024
    Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Eliseo VanoInstituto de Investigación Sanitaria del Hospital Clínico San Carlos and Medical Physics Service, Madrid, Spain.ORCID 0000-0002-1730-1358
José M Fernandez-SotoInstituto de Investigación Sanitaria del Hospital Clínico San Carlos and Medical Physics Service, Madrid, Spain.
José I TenInstituto de Investigación Sanitaria del Hospital Clínico San Carlos and Medical Physics Service, Madrid, Spain.
Roberto M Sanchez CasanuevaInstituto de Investigación Sanitaria del Hospital Clínico San Carlos and Medical Physics Service, Madrid, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThe International Commission on Radiological Protection recommends managing patient and occupational doses as an integrated approach, for the optimisation of interventional procedures. The conventional passive personal dosimeters only allow one to know the accumulated occupational doses during a certain period of time. This information is not enough to identify if there is a lack of occupational radiation protection during some procedures. This paper describes the use of a dose management system (DMS) allowing patient and occupational doses for individual procedures to be audited.

methodsThe DMS manages patient and occupational doses measured by electronic personal dosimeters. One dosemeter located at the C-arm is used as a reference for scatter radiation. Data have been collected from five interventional rooms. Dosimetry data can be managed for the whole procedure and the different radiation events. Optimisation is done through auditing different sets of parameters for individual procedures: patient dose indicators, occupational dose values, the ratio between occupational doses, and the doses measured by the reference dosemeter at the C-arm, and the ratio between occupational and patient dose values.

resultsThe managed data correspond to the year 2021, with around 4500 procedures, and 8000 records on occupational exposures. Patient and staff dose data (for 11 cardiologists, 7 radiologists and 8 nurses) were available for 3043 procedures. The DMS allows alerts for patient dose indicators and occupational exposures to be set.

conclusionsThe main advantage of this integrated approach is the capacity to improve radiation safety for patients and workers together, auditing alerts for individual procedures. ADVANCES IN KNOWLEDGE: The management of patient and occupational doses together (measured with electronic personal dosimeters) for individual interventional procedures, using dose management systems, allows alerting optimisation on high-dose values for patients and staff.

Indexed as

Occupational ExposureRadiation ProtectionHumansRadiation DosageRadiation DosimetersRadiology, InterventionalRadiometry

Identifiers

PMID36533561
PMCPMC9975364

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked