ArticleCureus2022
X-ray Target Shielding and Leakage Radiation Inside the Treatment Capsule of the Zap-X.
Article in Cureus, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 1 citations in OpenAlex.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The ZAP-X represents the first-of-its-kind "self-shielded" therapeutic radiation device, which by novelty, challenges regulators to accommodate it within the existing regulatory framework for radiation protection. To facilitate informed regulatory interpretation, X-ray radiation leakage from the ZAP-X was measured inside the shielded treatment capsule at the level of the patient and X-ray target plane. Measurements were performed on a clinically commissioned system calibrated for reference conditions to deliver 1cGy/MU. Radiation was measured with a FLUKE 451 survey meter and a RadCal ionization chamber as both exposure and dose and presented as a percentage of the system reference dose. Measurements were taken at thirteen locations, eight in the patient plane and five in the X-ray target plane. The results showed a maximum X-ray leakage of 0.000986% in the patient plane and 0.000907% in the target plane. These results are 30 - 100 times lower than existing recommendations as referenced by IEC guidelines standard 60601-2-1 (2020) for radiotherapy linear accelerators (LINACs). Although most conventional LINACs apply a safety factor of 2-5 to the design of collimator shielding and patient dose sparing, the ZAP-X delivers less than 10% of the patient whole body dose compared to this standard, originating from the X-ray target. Even though the ZAP-X intensity modulated radiation therapy (IMRT) factor is significantly higher than conventional Linacs, the absolute dose originating from leakage radiation remains lower by 25. The amount of unintended dose received by the patient's body distant from the isocenter is of interest from the perspective of both clinical and radiation safety. As this whole-body dose is decreased, the resulting treatment-related cancer incidence and mortality rates are decreased accordingly.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.