ArticleDigital health
Artificial intelligence-enabled electrocardiogram screens low left ventricular ejection fraction with a degree of confidence.
Article in Digital health. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 1 synthesis or guideline pooled it, 12 citations in OpenAlex.
- Deep learning and electrocardiography: systematic review of current techniques in cardiovascular disease diagnosis and management.Biomedical engineering online · 2025Pooled it
- Bridging the gap from clinical to home ECG: quantifying and overcoming accuracy loss in AI-enabled single-lead ECG models.NPJ digital medicine · 2026Article
- Deep learning analysis of 12-lead electrocardiograms for bloodstream infection prediction: a multi-center validation study.BMC medical informatics and decision making · 2026Article
- Personalized artificial intelligence based left ventricular ejection fraction and systolic dysfunction assessment.NPJ digital medicine · 2026Article
- Deep learning-enabled ECG system for detecting left ventricular hypertrophy and predicting cardiovascular prognoses.BioData mining · 2026Article
- Non-invasive hemoglobin estimation with outcome prediction via deep learning analysis of ECG-derived cardiac micro-dynamics.Internal and emergency medicine · 2026Article
- Artificial intelligence-enabled electrocardiography from scientific research to clinical application.EMBO molecular medicine · 2026Review
- Estimating LVEF from ECG with GPT-4o Fine-Tuned Vision: A Novel Approach in AI-Driven Cardiac Diagnostics.Journal of medical systems · 2025Article
- Real-world application of deep learning for ECG-based prediction of coronary artery disease and revascularization needs.European heart journal. Digital health · 2025Article
- Artificial intelligence in ECG-based diagnosis of low left ventricular ejection fraction: a systematic review and meta-analysis.Biomedical engineering letters · 2025Review
- Comprehensive review of non-invasive-treatment-related cardiovascular toxicity in breast cancer.iScience · 2025Review
- Artificial intelligence-enabled electrocardiography contributes to hyperthyroidism detection and outcome prediction.Communications medicine · 2024Article
- The robot butler: How and why should we study predictive algorithms and artificial intelligence (AI) in healthcare?Digital healthArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Artificial intelligence-enabled electrocardiogram has become a substitute tool for echocardiography in left ventricular ejection fraction estimation. However, the direct use of artificial intelligence-enabled electrocardiogram may be not trustable due to the uncertainty of the prediction. Objective: The study aimed to establish an artificial intelligence-enabled electrocardiogram with a degree of confidence to identify left ventricular dysfunction. Methods: The study collected 76,081 and 11,771 electrocardiograms from an academic medical center and a community hospital to establish and validate the deep learning model, respectively. The proposed deep learning model provided the point estimation of the actual ejection fraction and its standard deviation derived from the maximum probability density function of a normal distribution. The primary analysis focused on the accuracy of identifying patients with left ventricular dysfunction (ejection fraction ≤ 40%). Since the standard deviation was an uncertainty indicator in a normal distribution, we used it as a degree of confidence in the artificial intelligence-enabled electrocardiogram. We further explored the clinical application of estimated standard deviation and followed up on the new-onset left ventricular dysfunction in patients with initially normal ejection fraction. Results: The area under receiver operating characteristic curves (AUC) of detecting left ventricular dysfunction were 0.9549 and 0.9365 in internal and external validation sets. After excluding the cases with a lower degree of confidence, the artificial intelligence-enabled electrocardiogram performed better in the remaining cases in internal (AUC = 0.9759) and external (AUC = 0.9653) validation sets. For the application of future left ventricular dysfunction risk stratification in patients with initially normal ejection fraction, a 4.57-fold risk of future left ventricular dysfunction when the artificial intelligence-enabled electrocardiogram is positive in the internal validation set. The hazard ratio was increased to 8.67 after excluding the cases with a lower degree of confidence. This trend was also validated in the external validation set. Conclusion: The deep learning model with a degree of confidence can provide advanced improvements in identifying left ventricular dysfunction and serve as a decision support and management-guided screening tool for prognosis.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.