Evidence map›Paper›PMID 36531591›Full record

ArticleOphthalmology science2022

Deformation of Aflibercept and Ranibizumab Syringes Causes Variation in Intravitreal Injection Volume and Risks Retinal Tear Formation.

Joseph J Raevis, Colin A Lemire, David J Ramsey, James Riccobono, Efren Gonzalez

Open access · goldAbstract read
In one paragraph

Article in Ophthalmology science, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.2field-weighted citation impact, top 52% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 citations in OpenAlex.

  1. Article
  2. Intravitreal injection delivered volume under different environmental and training conditions.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Joseph J RaevisDepartment of Ophthalmology, Beth Israel Deaconess Medical Center, Boston, Massachusetts.
Colin A LemireDepartment of Ophthalmology, Beth Israel Deaconess Medical Center, Boston, Massachusetts.
David J RamseyDivision of Ophthalmology, Department of Surgery, Lahey Hospital & Medical Center, Peabody, Massachusetts.
James RiccobonoDepartment of Ophthalmology, Beth Israel Deaconess Medical Center, Boston, Massachusetts.
Efren GonzalezDepartment of Ophthalmology, Beth Israel Deaconess Medical Center, Boston, Massachusetts.
Beth Israel Deaconess Medical Center · USHarvard University · USTufts University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: The intravitreal injection volume is known to vary with plunger alignment and the speed of injection. We investigated the role that syringe stopper deformation plays in allowing excess volumes to be injected into the eye and the potential for the vitreous humor to become incarcerated when excess force is released within the eye. Design: Experimental study. Methods: Aflibercept prefilled syringes (PFSs), ranibizumab PFSs, and 1-ml tuberculin (TB) syringes were subjected to increasing injection force to assess the extent to which each design allowed for excess volumes to be expelled after the stopper reached the bottom of the syringe barrel (i.e., after the 50-μl dose was expelled). Main Outcome Measures: Additional volume expelled with stopper deformation. Results: Syringe stoppers are capable of deformation into the dead space when additional force is applied. This allows for progressively greater medication doses to be administered. At an additional force of 3.92 N after the syringe stopper came in contact with the bottom of the syringe barrel, the aflibercept PFSs, ranibizumab PFSs, and 1-ml TB syringes dispensed an additional 17.2%, 11.4%, and 0.8% higher volume than the intended volume of 50 μl, respectively. Upon release of this force, a proportional volume was observed to be drawn back into the needle. Conclusions: The intravitreal injection volume varies with the force applied to fully depressed syringes because of syringe stopper deformation. We advise that performing forceful intravitreal injections be avoided to prevent excessive dosing of medication. We also caution that pressure applied to the plunger during intravitreal injections not be released while the needle is in the vitreous cavity to guard against vitreous incarceration, which could lead to retinal tear formation or detachment.

Indexed as

afliberceptCI, confidence intervalIntravitreal injectionPFS, prefilled syringeSyringeTB, tuberculinVariabilityVolume

Identifiers

PMID36531591
PMCPMC9754977
OpenAlexW4285604447

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.