Evidence map›Paper›PMID 36523850›Full record

ArticleClinical ophthalmology (Auckland, N.Z.)2022

Accuracy and Correlation of the Kinect-Based Semi-Automatic Scoring Method for Measuring Anomalous Head Posture as Compared to the CROM

Mana Yamamoto, Teiji Yagasaki, Sho Ichikawa, Takuto Nakamura, Yuumi Konishi, Yoshimi Yokoyama

Open access · goldAbstract read
In one paragraph

Article in Clinical ophthalmology (Auckland, N.Z.), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.7field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 3 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Mana YamamotoDepartment of Ophthalmology, Japan Community Healthcare Organization Chukyo Hospital, Nagoya, Aichi, Japan.ORCID 0000-0002-6844-8392
Teiji YagasakiDepartment of Ophthalmology, Japan Community Healthcare Organization Chukyo Hospital, Nagoya, Aichi, Japan.ORCID 0000-0002-0038-2884
Sho IchikawaDepartment of Ophthalmology, Japan Community Healthcare Organization Chukyo Hospital, Nagoya, Aichi, Japan.
Takuto NakamuraDepartment of Mechano-Informatics, Graduate School of Information Science and Technology, The University of Tokyo, Tokyo, Japan.ORCID 0000-0003-3866-4745
Yuumi KonishiDepartment of Computer Science, School of Computing, Tokyo Institute of Technology, Tokyo, Japan.
Yoshimi YokoyamaDepartment of Ophthalmology, Japan Community Healthcare Organization Chukyo Hospital, Nagoya, Aichi, Japan.ORCID 0000-0003-1074-9624
Japan Community Healthcare Organization · JPJapan Society for the Promotion of Science · JPTokyo Institute of Technology · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: To determine the reliability of the Kinect-based semi-automatic scoring method (KSSM) using Kinect for Windows v2 for head posture compared to the cervical range-of-motion (CROM) device. Methods and Analysis: Head positions between -40° and +40° of chin up/down (X), head turn (Y), and lateral tilt (Z) were measured in 10° increments in healthy volunteers. Their head positions were simultaneously measured using the KSSM and CROM. The following four points were analyzed: the success rate of the KSSM, the correlation between the two methods, the comparison of results by 95% limits of agreement (LA), and proportional error at 95% LA. Results: The measurability of the KSSM for all positions within ±30° of the X, Y, and Z axes was 100%. The correlations for both methods were 0.979 (95% CI: 0.967-0.987), 0.985 (0.976-0.991), and 0.988 (0.981-0.993) for the X-, Y-, and Z-axes, respectively. The simple linear regression analysis equations for 95% LA were Y=-0.024X-0.452 for X axes, Y=0.024X-0.363 for Y axes, and Y=-0.045X+0.217 for Z axes (95% confidence interval for each axis: -0.055-0.007, -0.006-0.050, and -0.071-0.018). However, the proportional biases were small because the predictive values of the differences in head positions from -40° to 40° determined by the equations were within ± 5° for chin up/down and within ± 3° for head tilt. Conclusion: Head posture measurements using the KSSM and CROM were found to be similar when used in clinical settings.

Indexed as

anomalous head postureCROMKinectreliabilityspine

Identifiers

PMID36523850
PMCPMC9744893
OpenAlexW4310834145

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.