Evidence map›Paper›PMID 36523811›Full record

ArticleReports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology2022

Effects of metal implants and validation of four treatment planning methods used for radiotherapy dose calculation.

Amirtharaj Gnanasambandam, N Arunai Nambi Raj, Sollinselvan K

Open access · diamondAbstract read
In one paragraph

Article in Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.5field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 6 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Amirtharaj GnanasambandamDepartment of Radiation Oncology, MIOT Hospitals, Manapakkam, Chennai, India.
N Arunai Nambi RajSchool of Advanced Sciences, Vellore Institute of Technology, Vellore, India.
Sollinselvan KDepartment of Radiation Oncology, MIOT Hospitals, Manapakkam, Chennai, India.
Madras Institute of Orthopaedics and Traumatology · INVellore Institute of Technology University · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The radiotherapy treatment planning process involves target delineation and dose calculation, both of which directly depend on image quality and Hounsfield unit (HU) accuracy of computed tomography (CT) images. CT images of patients having metal implants undergo image quality deterioration and show inaccurate HU values due to various artifacts. Metal artifact reduction (MAR) is used to improve the image quality. In this study, four treatment planning methods with and without MAR, in combination with actual and assigned HU values, were analyzed for dose calculation accuracy. The aim was to study the effects of metal implants on planning CT and to evaluate the dose calculation accuracy of four treatment planning methods for radiotherapy. Materials and methods: Two phantoms with six different metal inserts were scanned in the extended HU mode, with and without MAR. Geometry verification and HU analysis of the metals and the surrounding region were carried out. Water equivalent distance (WED) measurements and dose calculation for each metal insert were done in the treatment planning system (TPS) using the anisotropic analytical algorithm (AAA). Point dose and two-dimensional dose distribution were studied. Percentage variation analysis between calculated and measured doses and gamma evaluation were conducted to determine the most suitable method for treatment planning. Conclusion: This study concludes that an MARCT image with an assigned HU similar to that of the metal implant is better for contouring and high dose calculation accuracy. If MAR is not available, the actual HU value from the extended HU CT for the metal should be used for dose calculation.

Indexed as

dose calculationextended Hounsfield unitmetal artifact reductionmetal implanttreatment planning

Identifiers

PMID36523811
PMCPMC9746644
OpenAlexW4310864241

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.