Evidence map›Paper›PMID 36522744›Full record

ArticleBMC musculoskeletal disorders2022

Arthroscopic repair of rotator cuff injury with bioabsorbable suture anchor vs. all-suture anchor: a non-inferiority study.

Stefano Di Gennaro, Domenico Lecce, Alessio Tarantino, Mauro De Cupis, Erica Bassetti, Pierpaolo Scarnera, Enrico Ciminello, Vittorio Calvisi

Open access · goldAbstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.7field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 9 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 2 countries.

Stefano Di GennaroPolo Sanitario San Feliciano, Rome, Italy.
Domenico LeccePolo Sanitario San Feliciano, Rome, Italy.
Alessio TarantinoUNIVAQ MeSVA: Università Degli Studi Dell'Aquila Dipartimento Di Medicina Clinica Sanita Pubblica Scienze Della Vita E Dell'Ambiente, Via Mattia Battistini, 44, 00167, Rome, RM, Italy. alessio.tarantino@email.it.ORCID http://orcid.org/0000-0001-5111-4815
Mauro De CupisDepartment of Orthopaedics and Traumatology, C.T.O. Hospital, Rome, Italy.
Erica BassettiDepartment of Radiological, Oncological and Pathological Sciences, La Sapienza" University of Rome, Rome, Italy.
Pierpaolo ScarneraUNIVAQ MeSVA: Università Degli Studi Dell'Aquila Dipartimento Di Medicina Clinica Sanita Pubblica Scienze Della Vita E Dell'Ambiente, Via Mattia Battistini, 44, 00167, Rome, RM, Italy.
Enrico CiminelloItalian Implantable Prostheses Registry, Scientific Secretary of the Presidency, Italian National Institute of Health, Rome, Italy.
Vittorio CalvisiUNIVAQ MeSVA: Università Degli Studi Dell'Aquila Dipartimento Di Medicina Clinica Sanita Pubblica Scienze Della Vita E Dell'Ambiente, Via Mattia Battistini, 44, 00167, Rome, RM, Italy.
University of L'Aquila · ITCTO Hospital · ITNational Institute of Health · AMSapienza University of Rome · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCompare all-suture anchors to traditional anchors through clinical and radiological evaluation at pre-established end-points. MATERIALS AND

methodsWe performed a two-arms non-inferiority study on all-suture anchor (2.3 iconix™, Stryker) device with respect to traditional anchor (5.5 healix Advance™ BR, Depuy/Mitek) device under unpaired samples with size equal to 30 patients per group, all suffering from supraspinatus tendon rupture. We administrated DASH (Disabilities of the Arm, Shoulder and Hand); constant; and SST (Simple Shoulder Test) questionnaires in pre-operative, 3 ± 1 months post-intervention and 8 ± 1 months post-intervention. Questionnaires scores were the primary outcome. We also evaluated RMI at 3 and at 8 months after surgery to assess the presence of oedema or any loosening of the implant.

resultsAll-suture anchor approach has been proven to have non-inferior performances with respect to traditional anchor approach, according to questionnaires scores at the 3-month endpoint. We observed 26 patients with oedema by MRI (18 in control group, 6 in experimental group). In the 8-month endpoint we found persistent edema in 12 patients (all treated with healix), 2 had mobilitazions (healix), 10 had partial retears (8 healix, 2 iconix) and 1 implant failure (healix).

conclusionsAll suture devices have clinical and functional results comparable to traditional devices, while they tend to give fewer complications in terms of bone edema, loosening and retear rate. The effectiveness of all-suture devices should be further investigated in rotator cuff suture arthroscopic revision surgery, given the advantages they offer.

Indexed as

Rotator Cuff InjuriesAbsorbable ImplantsArthroscopyHumansMagnetic Resonance ImagingRotator CuffSuture AnchorsSuturesSuture TechniquesAllsutureanchorArthroscopyBioabsorbableanchorRotatorcuffsurgeryShoulderarthroscopy

Identifiers

PMID36522744
PMCPMC9753362
OpenAlexW4311929847

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.