Evidence map›Paper›PMID 36522686›Full record

ArticleArthroplasty (London, England)2022

Posterior-stabilized total knee arthroplasty kinematics and joint laxity: A hybrid biomechanical study.

Allan R Sekeitto, Jance G McGale, Liam A Montgomery, Edward M Vasarhelyi, Ryan Willing, Brent A Lanting

Abstract read
In one paragraph

Article in Arthroplasty (London, England), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Exploration of the Advanced VIVOBioengineering (Basel, Switzerland) · 2024
    Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Allan R SekeittoLondon Health Sciences Centre, 339 Windermere Rd, London, ON, N6A 5A5, Canada. sekeitto@yahoo.com.ORCID http://orcid.org/0000-0002-5402-6500
Jance G McGaleLondon Health Sciences Centre, 339 Windermere Rd, London, ON, N6A 5A5, Canada.
Liam A MontgomeryDepartment of Mechanical & Materials Engineering, University of Western Ontario, 1151 Richmond Street N., London, ON, N6A 5B9, Canada.
Edward M VasarhelyiLondon Health Sciences Centre, 339 Windermere Rd, London, ON, N6A 5A5, Canada.
Ryan WillingDepartment of Mechanical & Materials Engineering, University of Western Ontario, 1151 Richmond Street N., London, ON, N6A 5B9, Canada.
Brent A LantingLondon Health Sciences Centre, 339 Windermere Rd, London, ON, N6A 5A5, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPosterior-stabilized (PS)-total knee arthroplasty (TKA) arose as an alternative to cruciate-retaining (CR)-TKA in the 1970s. Since then, it has become a popularly utilized TKA design with outcomes comparable to CR-TKA. The post-cam mechanism is unique to PS-TKA as it substitutes the function of the posterior cruciate ligament (PCL). The study aimed to understand the kinematic and laxity changes in PS-TKA with under- and overstuffing of the tibiofemoral joint space with the polyethylene (PE) insert.

methodsThis study employed a hybrid computational-experimental joint motion simulation on a VIVO 6 degrees of freedom (6-DoF) joint motion simulator (AMTI, Watertown, MA, USA). Physical prototypes of a virtually-performed TKA in mechanical alignment (MA) and kinematic alignment (KA) based on cadaveric CT scans and a virtual ligament model were utilized. The reference, understuffed (down 2 mm) and overstuffed (up 2 mm) joint spaces were simulated, neutral flexion and laxity testing loads and motions were performed for each configuration.

resultsThe PE insert thickness influenced post-cam engagement, which occurred after 60º in the overstuffed configurations, after 60º-75º in the reference configurations and after 75º in the understuffed configurations. The understuffed configurations, compared to the reference configurations, resulted in a mean 2.0º (28%) and 2.0º (31%) increase in the coronal laxity in MA and KA respectively. The overstuffed configurations, compared to the reference configuration, resulted in an increase in the mean joint compressive forces (JCFs) by 73 N (61%) and 77 N (62%) in MA and KA models, respectively.

conclusionsThe under- and overstuffing in PS-TKA alter the kinematics with variable effects. Understuffing decreases the stability, JCFs and inverse with overstuffing. Subtle changes in the PE insert thickness alter the post-cam mechanics.

Indexed as

Joint laxityJoint motion simulatorKinematicsPosterior-stabilized total knee arthroplasty (PS-TKA)Virtual ligament model

Identifiers

PMID36522686
PMCPMC9753369

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.