Evidence map›Paper›PMID 36520213›Full record

ArticleEuropean spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society2023

The use of electronic conductivity devices can effectively reduce radiation exposure in vertebral body tethering.

Stephanie Da Paz, Per Trobisch, Alice Baroncini

Open access · hybridAbstract read
PubMed Publisher
In one paragraph

Article in European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.5field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 7 citations in OpenAlex.

  1. Does screw alignment affect tether breakage in vertebral body tethering?European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2025
    Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. An investigation of range of motion preservation in fusionless anterior double screw and cord constructs for scoliosis correction.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2023
    Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Stephanie Da PazDepartment of Spine Surgery, Eifelklinik St. Brigida, Simmerath, Germany.
Per TrobischDepartment of Spine Surgery, Eifelklinik St. Brigida, Simmerath, Germany.
Alice BaronciniDepartment of Orthopaedics and Trauma Surgery, RWTH Aachen University Clinic, Pauwelsstrasse 30, 52074, Aachen, Germany. alice.baroncini@gmail.com.ORCID 0000-0002-4383-3470
RWTH Aachen University · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionVertebral body tethering (VBT) presents new challenges in respect to radiation exposure, as screws cannot be placed free-hand and the lateral positioning of the patients increases scattered radiation. To reduce radiation exposure, we introduced the use of electronic conductivity device (ECD). These are drilling probes send an audio signal when cortical bone is breached. Thus, anterior, bicortical screws can be placed without multiple fluoroscopic controls. ECD has been used for all VBT procedures at our institution starting April 2020. The aim of this study was to test the safety of ECD and its efficacy in radiation reduction in comparison with the current standard, the fluoroscopic guidance. MATERIALS AND

methodsAll patients who underwent VBT between August 2019 and December 2020 were retrospectively reviewed and divided into two groups according to whether ECD had been used or not. The radiation exposure per procedure and per screw was compared among the two groups, overall and separately for thoracic, lumbar and bilateral procedures. The rate of misplaced screws was calculated.

resultsData from 62 patients and 825 screws were obtained (397 with ECD). No screw misplacement was observed. Radiation reduction with ECD reached up to 41%. A significant reduction was observed in the radiation per procedure in bilateral instrumentation (from 9.16 to 5.52 mGy*m

conclusionECD can safely and effectively reduce the radiation exposure for VBT procedures.

Indexed as

Radiation ExposureScoliosisSpinal FusionBone ScrewsFluoroscopyHumansRetrospective StudiesThoracic VertebraeVertebral BodyAdolescent idiopathic scoliosisElectronic conductivity deviceRadiation exposureScoliosisVertebral body tethering

Identifiers

PMID36520213
OpenAlexW4311573636

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.