ArticleJournal of neuroengineering and rehabilitation2022

Human-prosthesis cooperation: combining adaptive prosthesis control with visual feedback guided gait.

Bretta L Fylstra, I-Chieh Lee, Minhan Li, Michael D Lewek, He Huang

Abstract read
In one paragraph

Article in Journal of neuroengineering and rehabilitation, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Bretta L Fylstra *Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC, 27695, USA.
I-Chieh Lee *Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC, 27695, USA.
Minhan LiJoint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC, 27695, USA.
Michael D LewekDivision of Physical Therapy, UNC Chapel Hill, Chapel Hill, NC, 27599, USA.
He HuangJoint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC, 27695, USA. hhuang11@ncsu.edu.

Funding

Error Tolerance in Wearer-Robot SystemsR01EB024570 · NIBIB · NORTH CAROLINA STATE UNIVERSITY RALEIGH · PI HUANG, HE · 2018 to 2022
$1.8M
NIH HHS R01EB024570
6 · The paper itself

Abstract

backgroundPersonalizing prosthesis control is often structured as human-in-the-loop optimization. However, gait performance is influenced by both human control and intelligent prosthesis control. Hence, we need to consider both human and prosthesis control, and their cooperation, to achieve desired gait patterns. In this study, we developed a novel paradigm that engages human gait control via user-fed visual feedback (FB) of stance time to cooperate with automatic prosthesis control tuning. Three initial questions were studied: (1) does user control of gait timing (via visual FB) help the prosthesis tuning algorithm to converge faster? (2) in turn, does the prosthesis control influence the user's ability to reach and maintain the target stance time defined by the feedback? and (3) does the prosthesis control parameters tuned with extended stance time on prosthesis side allow the user to maintain this potentially beneficial behavior even after feedback is removed (short- and long-term retention)?

methodsA reinforcement learning algorithm was used to achieve prosthesis control to meet normative knee kinematics in walking. A visual FB system cued the user to control prosthesis-side stance time to facilitate the prosthesis tuning goal. Seven individuals without amputation (AB) and four individuals with transfemoral amputation (TFA) walked with a powered knee prosthesis on a treadmill. Participants completed prosthesis auto-tuning with three visual feedback conditions: no FB, self-selected stance time FB (SS FB), and increased stance time FB (Inc FB). The retention of FB effects was studied by comparing the gait performance across three different prosthesis controls, tuned with different visual FB.

results(1) Human control of gait timing reduced the tuning duration in individuals without amputation, but not for individuals with TFA. (2) The change of prosthesis control did not influence users' ability to reach and maintain the visual FB goal. (3) All participants increased their prosthesis-side stance time with the feedback and maintain it right after feedback was removed. However, in the post-test, the prosthesis control parameters tuned with visual FB only supported a few participants with longer stance time and better stance time symmetry.

conclusionsThe study provides novel insights on human-prosthesis interaction when cooperating in walking, which may guide the future successful adoption of this paradigm in prosthesis control personalization or human-in-the-loop optimization to improve the prosthesis user's gait performance.

Indexed as

AmputeesArtificial LimbsBiomechanical PhenomenaFeedback, SensoryGaitHumansProsthesis DesignWalkingGaitHuman-in-the-loop optimizationPowered prosthesis tuningTransfemoral amputeeVisual feedback

Identifiers

PMID36517814
PMCPMC9753428

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.