ArticleThe ultrasound journal2022
Measuring the accuracy of cardiac output using POCUS: the introduction of artificial intelligence into routine care.
Article in The ultrasound journal, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
19 citing papers in PubMed, 32 citations in OpenAlex.
- Cross-sectional evaluation of cardiovascular biological age using point-of-care ultrasound.European heart journal. Digital health · 2026Article
- Feasibility of measuring left ventricular outflow tract velocity time integral as a predictor for stroke volume in pregnant women in labor.The ultrasound journal · 2026Article
- Structural heart disease screening using artificial intelligence-enabled electrocardiogram and novice handheld cardiac ultrasound: a cost analysis.European heart journal open · 2026Article
- Rapid bedside multimodal ultrasound screening for acute type A aortic dissection: a perspective.Frontiers in cardiovascular medicine · 2026Article
- Point-of-care ultrasound: Uniting cardiology and nephrology at the bedside.World journal of cardiology · 2025Review
- Trust of Artificial Intelligence-Augmented Point-of-Care Ultrasound Among Pediatric Emergency Physicians.Journal of the American College of Emergency Physicians open · 2025Article
- Point-of-Care Ultrasound Use in Hemodynamic Assessment.Biomedicines · 2025Review
- Overcoming barriers in the use of artificial intelligence in point of care ultrasound.NPJ digital medicine · 2025Review
- Deep learning in renal ultrasound: applications, challenges, and future outlook.Frontiers in oncology · 2025Review
- Critical care ultrasound: development, evolution, current and evolving clinical concepts in critical care medicine.Frontiers in medicine · 2025Review
- Revolutionizing Bladder Health: Artificial-Intelligence-Powered Automatic Measurement of Bladder Volume Using Two-Dimensional Ultrasound.Diagnostics (Basel, Switzerland) · 2024Article
- Critical Advances for Democratizing Ultrasound Diagnostics in Human and Veterinary Medicine.Annual review of biomedical engineering · 2024Review
- Recent advances in cardiorespiratory monitoring in acute respiratory distress syndrome patients.Journal of intensive care · 2024Review
- Artificial Intelligence-Based Left Ventricular Ejection Fraction by Medical Students for Mortality and Readmission Prediction.Diagnostics (Basel, Switzerland) · 2024Article
- Ultrasonographic Applications of Novel Technologies and Artificial Intelligence in Critically Ill Patients.Journal of personalized medicine · 2024Review
- Role of artificial intelligence in haemodynamic monitoring.Indian journal of anaesthesia · 2024Article
- A nursing-led sepsis response team guiding resuscitation with point-of-care ultrasound: A review and model for improving bundle compliance while individualizing sepsis care.SAGE open medicine · 2024Review
- Artificial intelligence (AI) versus expert: A comparison of left ventricular outflow tract velocity time integral (LVOT-VTI) assessment between ICU doctors and an AI tool.Journal of applied clinical medical physics · 2022Article
- Automated versus manual B-lines counting, left ventricular outflow tract velocity time integral and inferior vena cava collapsibility index in COVID-19 patients.Indian journal of anaesthesia · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 5 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundShock management requires quick and reliable means to monitor the hemodynamic effects of fluid resuscitation. Point-of-care ultrasound (POCUS) is a relatively quick and non-invasive imaging technique capable of capturing cardiac output (CO) variations in acute settings. However, POCUS is plagued by variable operator skill and interpretation. Artificial intelligence may assist healthcare professionals obtain more objective and precise measurements during ultrasound imaging, thus increasing usability among users with varying experience. In this feasibility study, we compared the performance of novice POCUS users in measuring CO with manual techniques to a novel automation-assisted technique that provides real-time feedback to correct image acquisition for optimal aortic outflow velocity measurement.
methods28 junior critical care trainees with limited experience in POCUS performed manual and automation-assisted CO measurements on a single healthy volunteer. CO measurements were obtained using left ventricular outflow tract (LVOT) velocity time integral (VTI) and LVOT diameter. Measurements obtained by study subjects were compared to those taken by board-certified echocardiographers. Comparative analyses were performed using Spearman's rank correlation and Bland-Altman matched-pairs analysis.
resultsAdequate image acquisition was 100% feasible. The correlation between manual and automated VTI values was not significant (p = 0.11) and means from both groups underestimated the mean values obtained by board-certified echocardiographers. Automated measurements of VTI in the trainee cohort were found to have more reproducibility, narrower measurement range (6.2 vs. 10.3 cm), and reduced standard deviation (1.98 vs. 2.33 cm) compared to manual measurements. The coefficient of variation across raters was 11.5%, 13.6% and 15.4% for board-certified echocardiographers, automated, and manual VTI tracing, respectively.
conclusionsOur study demonstrates that novel automation-assisted VTI is feasible and can decrease variability while increasing precision in CO measurement. These results support the use of artificial intelligence-augmented image acquisition in routine critical care ultrasound and may have a role for evaluating the response of CO to hemodynamic interventions. Further investigations into artificial intelligence-assisted ultrasound systems in clinical settings are warranted.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.