Evidence map›Paper›PMID 36511067›Full record

ArticleJournal of Indian Prosthodontic Society

Stability of implant-abutment connection in three different systems after fatigue test.

Farshad Bajoghli, Mohmoud Sabouhi, Mohamad Pourali, Amin Davoudi

Abstract read
In one paragraph

Article in Journal of Indian Prosthodontic Society. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Farshad BajoghliDental Implants Research Center, Department of Prosthodontics, Dental Research Institute, Isfahan University of Medical Sciences, Isfahan, Iran.
Mohmoud SabouhiDental Materials Research Center, Department of Prosthodontics, Dental Research Institute, Isfahan University of Medical Sciences, Isfahan, Iran.
Mohamad PouraliDepartment of Prosthodontics, School of Dentistry, Qom, Iran.
Amin DavoudiDepartment of Prosthodontics, School of Dentistry, Shahrekord University of Medical Sciences, Shahrekord, Iran.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aim: Abutment screw loosening of implant-supported prosthesis causes a mismatch between the abutment and the implant. This screw loosening is influenced by the implant-abutment connection type, however, with contradictory results reported in different studies. The present study evaluates the stability of abutment-implant connections in three different systems before and after the fatigue test. Settings and Design: Thirty implants (4.3 mm in diameter and 12 mm in length) were divided into three groups of 10: Implantium, Zimmer, and straight internal hexagonal connection (SIC) implants. Materials and Methods: Two torques of 35 Ncm with an interval of 10 min were applied, followed by measuring removal torque value (RTV). The samples were re-torqued and then underwent a simulation of 1-year chewing clinical performance of dental implant under axial force of 400 N, with a frequency of 8 Hz (one million cycles). After fatigue test, the RTV was calculated and recorded. Statistical Analysis: The mean RTVs obtained before and after cyclic load were analyzed by SPSS version 22 software using multivariate analysis. Results: Significant differences in RTV and role of cyclic loading were found between SIC and Implantium groups (P = 0.006 and 0.021, respectively), as well as between Zimmer and SIC groups (P = 0.032 and 0.006, respectively), but not between Zimmer and Implantium groups (P = 0.771 and 0.248, respectively). Conclusion: The type of connection could affect the screw loosening, the preload loss, and the implant component stability. SIC group revealed the highest RTVs before and after cyclic loading.

Indexed as

Dental AbutmentsDental Implant-Abutment DesignBone ScrewsDental Stress AnalysisTorqueDental implantfatiguereverse torquescrew loosening

Identifiers

PMID36511067
PMCPMC9709864

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.