Evidence map›Paper›PMID 36510599›Full record

Trial reportClinical ophthalmology (Auckland, N.Z.)2022

The EVO ICL for Moderate Myopia: Results from the US FDA Clinical Trial.

Mark Packer

Abstract readCase ReportsClinical Trial
In one paragraph

Trial report in Clinical ophthalmology (Auckland, N.Z.), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. A pilot study of deep learning for automatic contouring of sulcus-to-sulcus diameter in ultrasound biomicroscopy.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2025
    Article
  7. Observational
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Mark PackerPacker Research Associates, Boulder, CO, USA.ORCID 0000-0003-2681-6641

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To evaluate the safety and effectiveness of collamer posterior chamber phakic refractive lenses with a central port design (EVO and EVO+ Sphere and Toric implantable collamer lenses [ICLs]) for correction of moderate myopia with or without astigmatism. Patients and Methods: Six-month results of a multicenter clinical trial were performed under United States FDA Investigational Device Exemption. Subjects 21 through 45 years of age with manifest refraction spherical equivalent ranging from -3.00 D to -6.00 D and astigmatism up to 4.00 D underwent implantation of EVO or EVO+ Sphere or Toric ICLs. Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, manifest refraction, intraocular pressure (IOP), endothelial cell density, and adverse events were evaluated over 6 months. Results: This report includes a retrospective review of 200 eyes of 114 subjects with mean age 35.1 ± 5.1 years that completed the 6-month visit. Mean preoperative spherical equivalent (SE) measured -4.61 ± 0.87 D (range: -3.00 to -6.00 D). At 6 months, mean SE was -0.085 ± 0.26 D, with 91.5% within ± 0.50 D of target and 100.0% within ±1.00 D of target. Mean postoperative UDVA and CDVA were -0.065 ± 0.08 logMAR and -0.14 ± 0.07 logMAR, respectively. About 98.0% of eyes maintained or gained lines of CDVA, and no eye lost more than 1 line CDVA. Efficacy and safety indices were 1.03 and 1.21, respectively. No eye experienced pupillary block, required preoperative or postoperative peripheral iridotomy or iridectomy, developed anterior subcapsular cataract or had elevated IOP due to angle narrowing or pigment dispersion. Mean endothelial cell density declined by 2.2%. Conclusion: EVO ICL lenses demonstrated accuracy, predictability and stability of refractive correction with achievement of high levels of UDVA and an excellent safety profile for patients with moderate myopia with or without astigmatism.

Indexed as

astigmatismimplantable collamer lensmoderate myopiaphakic refractive lens

Identifiers

PMID36510599
PMCPMC9738966

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked