Results of mitral valve reconstruction using substitute extracellular matrix.

Maria Ascaso Arbona, Tirone E David, Carolyn M David, Vivek Rao

Abstract read
In one paragraph

Article in JTCVS techniques, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Commando procedure in cardiac surgery: a narrative review.General thoracic and cardiovascular surgery · 2025
    Pooled it
  2. Article
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Maria Ascaso ArbonaDivision of Cardiovascular Surgery, Peter Munk Cardiac Centre, University Health Network and the Department of Surgery, University of Toronto, Toronto, Ontario, Canada.
Tirone E DavidDivision of Cardiovascular Surgery, Peter Munk Cardiac Centre, University Health Network and the Department of Surgery, University of Toronto, Toronto, Ontario, Canada.
Carolyn M DavidDivision of Cardiovascular Surgery, Peter Munk Cardiac Centre, University Health Network and the Department of Surgery, University of Toronto, Toronto, Ontario, Canada.
Vivek RaoDivision of Cardiovascular Surgery, Peter Munk Cardiac Centre, University Health Network and the Department of Surgery, University of Toronto, Toronto, Ontario, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: During the ongoing search for an ideal patch material for reconstructive heart surgery, several versions of extracellular matrix (ECM) have been used. However, long-term performance in different cardiac positions is unknown. Methods: We performed a retrospective review of outcomes after mitral valve surgery using ECM in 29 patients from 2011 to 2014. Clinical and echocardiographic follow-up was reviewed (mean time, 6.3 ± 2.8 years). Results: ECM was used to reconstruct the posterior mitral annulus in 69% and to repair the mitral leaflet in 65% of the patients. The most prevalent etiology was dystrophic calcification of the annulus (80%) versus endocarditis for leaflet repair (60%). Fifty-five percent of the patients who required annular reconstruction received a mitral valve replacement (MVR). There were 2 perioperative deaths (7%). Long-term data were analyzed according to surgical technique; namely, isolated leaflet repair compared with annular reconstruction with or without MVR. There were 3 late deaths (1 per group). Overall survival was 83% at 7 years. Ninety percent of cases with mitral valve repair with or without annular reconstruction were free from more than mild mitral regurgitation, compared with 45% in the MVR and annular reconstruction group. The mechanism of failure was patch degeneration creating a severe paravalvular leak due to prosthesis dehiscence. Conclusions: ECM used to repair the mitral valve leaflets with or without annular reconstruction offers acceptable results. However, caution should be taken with the use of ECM adjacent to prosthetic valve material because of a high rate of failure associated with patch degeneration.

Indexed as

ECM, extracellular matrixextracellular matrixmitral valve repairMR, mitral regurgitationMV, mitral valveMVr, mitral valve repairMVR, mitral valve replacementpatch material

Identifiers

PMID36510520
PMCPMC9735417

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.