Evidence map›Paper›PMID 36509946›Full record

ArticleSurgical endoscopy2023

Face, content, and construct validity of the virtual immersive operating room simulator for training laparoscopic procedures.

Fernando Pérez-Escamirosa, Damaris Areli García-Cabra, José Ricardo Ortiz-Hernández, Salvador Montoya-Alvarez, Eduardo Alfredo Ruíz-Vereo, Ricardo Manuel Ordorica-Flores, Arturo Minor-Martínez, Jesús Tapia-Jurado

Abstract read
PubMed Publisher
In one paragraph

Article in Surgical endoscopy, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.7field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 1 country.

Fernando Pérez-Escamirosa *Instituto de Ciencias Aplicadas y Tecnología (ICAT), Universidad Nacional Autónoma de México (UNAM), Circuito Exterior S/N, Ciudad Universitaria, Coyoacán, 04510, Mexico City, Mexico. fernando.perez@icat.unam.mx.ORCID 0000-0001-7886-8692
Damaris Areli García-Cabra *Instituto de Ciencias Aplicadas y Tecnología (ICAT), Universidad Nacional Autónoma de México (UNAM), Circuito Exterior S/N, Ciudad Universitaria, Coyoacán, 04510, Mexico City, Mexico.
José Ricardo Ortiz-Hernández *Servicio de Cirugía Pediátrica, Hospital Infantil de México Federico Gómez, Calle Dr. Márquez No. 162, Cuauhtémoc, Doctores, 06720, Mexico City, Mexico.
Salvador Montoya-AlvarezSección de Bioelectrónica, Departamento de Ingeniería Eléctrica, Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional (CINVESTAV-IPN), Av. IPN 2508, Col. San Pedro Zacatenco, 07360, Mexico City, México.
Eduardo Alfredo Ruíz-VereoDivisión de Ingeniería en Computación, Facultad de Estudios Superiores Aragón, Universidad Nacional Autónoma de México (UNAM), Av. Hacienda de Rancho Seco S/N, Impulsora Popular Avícola, 57130, Netzahualcóyotl, Estado de Mexico, Mexico.
Ricardo Manuel Ordorica-FloresServicio de Cirugía Pediátrica, Hospital Infantil de México Federico Gómez, Calle Dr. Márquez No. 162, Cuauhtémoc, Doctores, 06720, Mexico City, Mexico.
Arturo Minor-MartínezSección de Bioelectrónica, Departamento de Ingeniería Eléctrica, Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional (CINVESTAV-IPN), Av. IPN 2508, Col. San Pedro Zacatenco, 07360, Mexico City, México.
Jesús Tapia-JuradoDivisión de Estudios de Posgrado, Facultad de Medicina, Unidad de Simulación de Posgrado, Universidad Nacional Autónoma de México (UNAM), Circuito de los Posgrados S/N, C.U., Coyoacán, 04510, Mexico City, Mexico.
Universidad Nacional Autónoma de México · MXHospital Infantil de México Federico Gómez · MXInstituto Politécnico Nacional · MXUniversidad Veracruzana · MX

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe aim of this work is to present the face, content, and construct validation of the virtual immersive operating room simulator (VIORS) for procedural training of surgeons' laparoscopic psychomotor skills and evaluate the immersive training experience.

methodsThe VIORS simulator consists of an HMD Oculus Rift 2016 with a visor on a 1080 × 1200 pixel OLED screen, two positioning sensors with two adapted controls to simulate laparoscopic instruments, and an acrylic base to simulate the conventional laparoscopic setup. The immersion consists of a 360° virtual operating room environment, based on the EndoSuite at Hospital Infantil de Mexico Federico Gomez, which reproduces a configuration of equipment, instruments, and common distractions in the operating room during a laparoscopic cholecystectomy procedure. Forty-five surgeons, residents, and medicine students participated in this study: 27 novices, 13 intermediates, and 5 experts. They completed a questionnaire on the realism and operating room immersion, as well as their capabilities for laparoscopic procedural training, scored in the 5-point Likert scale. The data of instrument movement were recorded and analyzed using 13 movement analysis parameters (MAPs). The experience during training with VIORS was evaluated through NASA-TLX.

resultsThe participants were enthusiastic about the immersion and sensation levels of the VIORS simulator, with positive scores on the realism and its capabilities for procedural training using VIORS. The results proved that the VIORS simulator was able to differentiate between surgeons with different skill levels. Statistically significant differences were found in nine MAPs, demonstrating their construct validity for the objective assessment of the procedural laparoscopic performance. At cognitive level, the inversion experience proves a moderate mental workload when the laparoscopic procedure is carried out.

conclusionThe VIORS simulator has been successfully presented and validated. The VIORS simulator is a useful and effective device for the training of procedural laparoscopic psychomotor skills.

Indexed as

Cholecystectomy, LaparoscopicLaparoscopyClinical CompetenceComputer SimulationHumansOperating RoomsUser-Computer InterfaceCognitive simulationImmersive virtual realityLaparoscopic simulatorSurgical trainingValidationVIORS

Identifiers

PMID36509946
OpenAlexW4311182690

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.