Evidence map›Paper›PMID 36509101›Full record

ArticleJournal of reconstructive microsurgery2023

Intraoperative Ergonomic Assessment of Exoscopes versus Conventional DIEP Flap.

Tianke Wang, Hamid Norasi, Minh-Doan Nguyen, Christin Harless, Katherine E Law, Tianqi G Smith, Emmanuel Tetteh, Susan Hallbeck

Open access · hybridAbstract read
In one paragraph

Article in Journal of reconstructive microsurgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
1.5field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it, 8 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Tianke WangRobert D. and Patricia E. Kern Center for the Science of Healthcare Delivery, Mayo Clinic, Rochester, Minnesota.
Hamid NorasiRobert D. and Patricia E. Kern Center for the Science of Healthcare Delivery, Mayo Clinic, Rochester, Minnesota.
Minh-Doan NguyenDepartment of Surgery, Mayo Clinic, Rochester, Minnesota.
Christin HarlessDepartment of Surgery, Mayo Clinic, Rochester, Minnesota.
Katherine E LawRobert D. and Patricia E. Kern Center for the Science of Healthcare Delivery, Mayo Clinic, Rochester, Minnesota.
Tianqi G SmithRobert D. and Patricia E. Kern Center for the Science of Healthcare Delivery, Mayo Clinic, Rochester, Minnesota.
Emmanuel TettehRobert D. and Patricia E. Kern Center for the Science of Healthcare Delivery, Mayo Clinic, Rochester, Minnesota.
Susan HallbeckRobert D. and Patricia E. Kern Center for the Science of Healthcare Delivery, Mayo Clinic, Rochester, Minnesota.
Mayo Clinic in Florida · USMayo Clinic · USMayo Clinic in Arizona · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThis study compared the ergonomics of surgeons during deep inferior epigastric perforator (DIEP) flap surgery using either baseline equipment (loupes, headlights, and an operating microscope) or an exoscope. Plastic surgeons may be at high risk of musculoskeletal problems. Recent studies indicate that adopting an exoscope may significantly improve surgeon postures and ergonomics.

methodsPostural exposures, using inertial measurement units at the neck, torso, and shoulders, were calculated in addition to the surgeons' subjective physical and cognitive workload. An ergonomic risk score on a scale of 1 (lowest) to 4 (highest) was calculated for each of the postures observed. Data from 23 bilateral DIEP flap surgeries (10 baseline and 13 exoscope) were collected.

resultsThe neck and torso risk scores decreased significantly during abdominal flap harvest and chest dissection, while right shoulder risk scores increased during the abdominal flap harvest for exoscope DIEP flap procedures compared with. Exoscope anastomoses demonstrated higher neck, right shoulder, and left shoulder risk scores. The results from the survey for the "surgeon at abdomen" showed that the usage of exoscopes was associated with decreased performance and increased mental demand, temporal demand, and effort. However, the results from the "surgeon at chest" showed that the usage of exoscopes was associated with lower physical demand and fatigue, potentially due to differences in surgeon preference.

conclusionOur study revealed some objective evidence for the ergonomic benefits of exoscope; however, this is dependent on the tasks the surgeon is performing. Additionally, personal preferences may be an important factor to be considered in the ergonomic evaluation of the exoscope.

Indexed as

MammaplastyPerforator FlapAbdomenEpigastric ArteriesErgonomicsNeck

Identifiers

PMID36509101
PMCPMC10266905
OpenAlexW4311221323

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.