Evidence map›Paper›PMID 36507554›Full record

ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2023

Stimuli-Responsive Sponge for Imaging and Measuring Weak Compression Stresses.

Nahoko Ono, Ryo Seishima, Koji Okabayashi, Hiroaki Imai, Syuji Fujii, Yuya Oaki

Abstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Stimuli-Responsive Sponge for Imaging and Measuring Weak Compression Stresses.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Nahoko OnoDepartment of Applied Chemistry, Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama, 223-8522, Japan.
Ryo SeishimaDepartment of Surgery, School of Medicine, Keio University, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan.
Koji OkabayashiDepartment of Surgery, School of Medicine, Keio University, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan.
Hiroaki ImaiDepartment of Applied Chemistry, Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama, 223-8522, Japan.
Syuji FujiiDepartment of Applied Chemistry, Faculty of Engineering, Osaka Institute of Technology, 5-16-1 Omiya, Asahi-ku, Osaka, 535-8585, Japan.ORCID 0000-0003-2562-9502
Yuya OakiDepartment of Applied Chemistry, Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama, 223-8522, Japan.ORCID 0000-0001-7387-9237

Funding

AMED JP21lm0203012j0003Asahi Glass FoundationGrant-in-Aid for Scientific Research B (JSPS KAKENHI) 22H02148Nakatani Foundation, Grant Program for Biomedical Engineering Research
6 · The paper itself

Abstract

Imaging and measuring compression stresses secure a safe and healthy life. Compression stresses in kPa range are not easily detected by conventional mechanoresponsive materials because microscopic molecular motion of the chromophores is not induced by such weak stresses. Moreover, imaging of the stress distribution is not achieved so far. The present study shows a sponge device combining two stimuli-responsive materials, a capsule releasing interior liquid and color-changing polymer in responses to compression stress and chemical stimulus, respectively. The stimuli-responsive capsule is dispersed on a melamine sponge comprised of the fibers with coating the layered polydiacetylene (PDA). The application of weak compression stresses induces collapse of the capsules, outflow of the interior liquid, and subsequent irreversible color change of PDA. The cascading response in the sponge device colorimetrically enables imaging of the distribution and measuring the strength of the compression stresses in kPa range. Furthermore, the device demonstrates imaging and measuring unknown weak compression stresses applied by the irregular-shaped objects. A couple of clinical issues in surgical operation of intestine are studied using the stress-imaging sponge device. The device and its design strategy can be applied to stress imaging in a variety of fields.

Indexed as

Diagnostic ImagingPolymersPhysical PhenomenaPolyacetylene PolymerPolyacetylene PolymerpolydiacetylenePolymerslayered materialspolydiacetylenesponge devicesstimuli responsivenessstress imaging

Identifiers

PMID36507554
PMCPMC9875629

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.