Evidence map›Paper›PMID 36507112›Full record

ArticleCureus2022

Call to Action: Creating Resources for Radiology Technologists to Capture Higher Quality Portable Chest X-rays.

Michael X Jin, Kevin Gilotra, Austin Young, Elaine Gould

Open access · diamondAbstract read
In one paragraph

Article in Cureus, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.6field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Michael X JinRadiology, Stony Brook University Hospital, Stony Brook, USA.
Kevin GilotraRadiology, Stony Brook University Hospital, Stony Brook, USA.
Austin YoungRadiology, Stony Brook University Hospital, Stony Brook, USA.
Elaine GouldRadiology, Stony Brook University Hospital, Stony Brook, USA.
Stony Brook University Hospital · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background Patient rotation, foreign body overlying anatomy, and anatomy out of field of view can have detrimental impacts on the diagnostic quality of portable chest x-rays (PCXRs), especially as the number of PCXR imaging increases due to the coronavirus disease 2019 (COVID-19) pandemic. Although preventable, these "quality failures" are common and may lead to interpretative and diagnostic errors for the radiologist. Aims In this study, we present a baseline quality failure rate of PCXR imaging as observed at our institution. We also conduct a focus group highlighting the key issues that lead to the problematic images and discuss potential interventions targeting technologists that can be implemented to address imaging quality failure rate. Materials and methods A total of 500 PCXRs for adult patients admitted to a large university hospital between July 12, 2021, and July 25, 2021, were obtained for evaluation of quality. The PCXRs were evaluated by radiology residents for failures in technical image quality. The images were categorized into various metrics including the degree of rotation and obstruction of anatomical structures. After collecting the data, a focus group involving six managers of the technologist department at our university hospital was conducted to further illuminate the key barriers to quality PCXRs faced at our institution.. Results  Out of the 500 PCXRs evaluated, 231 were problematic (46.2%). 43.5% of the problematic films with a repeat PCXR within one week showed that there was a technical problem impacting the ability to detect pathology. Most problematic films also occurred during the night shift (48%). Key issues that lead to poor image quality included improper patient positioning, foreign objects covering anatomy, and variances in technologists' training. Three interventions were proposed to optimize technologist performance that can lower quality failure rates of PCXRs. These include a longitudinal educational curriculum involving didactic sessions, adding nursing support to assist technologists, and adding an extra layer of verification by internal medicine residents before sending the films to the radiologist. The rationale for these interventions is discussed in detail so that a modified version can be implemented in other hospital systems.  Conclusion This study illustrates the high baseline error rate in image quality of PCXRs at our institution and demonstrates the need to improve on image quality. Poor image quality negatively impacts the interpretive accuracy of radiologists and therefore leads to wrong diagnoses. Increasing educational resources and support for technologists can lead to higher image quality and radiologist accuracy.

Indexed as

covid-19imagingimaging qualitymedical educationmedical errorsmedical qualitypcxrportable chest x-raysradiologyradiology technologists

Identifiers

PMID36507112
PMCPMC9731552
OpenAlexW4296240800

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.