Evidence map›Paper›PMID 36506620›Full record

ArticleJournal of conservative dentistry : JCD

Push-out bond strength of mineral trioxide aggregate with addition of titanium dioxide, silver, and silicon dioxide nanoparticles: An

Mugdha Laxmikant Bichile, Rushikesh Mahaparale, Sudha Mattigatti, Kapil D Wahane, Swati Vasant Raut

Abstract read
In one paragraph

Article in Journal of conservative dentistry : JCD. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Review
  3. AnJournal of conservative dentistry and endodontics · 2025
    Article
  4. Article
  5. Article
  6. Article
  7. Nanorevolution: Trends and future perspectives.Journal of conservative dentistry and endodontics · 2024
    Article
  8. Review
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Mugdha Laxmikant BichileDepartment of Conservative Dentistry and Endodontics, School of Dental Sciences, KIMSDU, Karad, Maharashtra, India.
Rushikesh MahaparaleDepartment of Conservative Dentistry and Endodontics, School of Dental Sciences, KIMSDU, Karad, Maharashtra, India.
Sudha MattigattiDepartment of Conservative Dentistry and Endodontics, School of Dental Sciences, KIMSDU, Karad, Maharashtra, India.
Kapil D WahaneDepartment of Conservative Dentistry and Endodontics, School of Dental Sciences, KIMSDU, Karad, Maharashtra, India.
Swati Vasant RautDepartment of Conservative Dentistry and Endodontics, School of Dental Sciences, KIMSDU, Karad, Maharashtra, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The ultimate goal of endodontic therapy is to eliminate all microorganisms present inside root canal and thereby sealing all the possible communicating pathways between pulpal and periradicular tissues, which prevents all the factors that cause recontamination and reinfection of the root canal system. If endodontic treatment fails, next approach is surgical endodontics. Bioceramics are recently introduced materials specifically designed for their potential use in medical field and dentistry. Aim: To evaluate and compare the push-out bond strength of mineral trioxide aggregate (MTA) by adding titanium dioxide (TiO2), silver, and silicon dioxide nanoparticles. Materials and Methods: Totally, 60 single-rooted human teeth were used. Middle third of the root was sectioned to obtain 2-mm thick root section. Acrylic was adapted to the section to obtain disks of 5 mm diameter and 2 mm thickness. Canal was prepared by GG Drill. Samples were divided into four groups of 15 each ( Statistical Analysis Used: The data were analyzed statistically by analysis of variance and Results: The highest push-out bond strength was shown by Group II (MTA with TiO2 nanoparticles), followed by Group III (MTA with silver nanoparticles) and Group I (MTA control group). The lowest push-out bond strength was shown by Group III (MTA with silicon dioxide nanoparticles). Conclusions: TiO

Indexed as

Mineral trioxide aggregatepush-out bond strengthsilicon dioxide nanoparticlessilver nanoparticlestitanium dioxide nanoparticles

Identifiers

PMID36506620
PMCPMC9733541

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.