Evidence map›Paper›PMID 36504244›Full record

SynthesisNeurosurgical review2022

Learning curves in robotic neurosurgery: a systematic review.

Nathan A Shlobin, Jonathan Huang, Chengyuan Wu

Abstract readSystematic Review
PubMed Publisher
In one paragraph

Synthesis in Neurosurgical review, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 3 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed, 3 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 3 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Usefulness of Robotic Stereotactic Assistance (ROSANeurologia medico-chirurgica · 2024
    Pooled it
  4. Article
  5. Article
  6. Review
  7. Review
  8. Article
  9. Article
  10. Review
  11. Review
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Nathan A ShlobinDepartment of Neurological Surgery, Northwestern University Feinberg School of Medicine, 676 N. St. Clair Street, Suite 2210, Chicago, IL, 60611, USA. nathan.shlobin@northwestern.edu.
Jonathan HuangDepartment of Neurological Surgery, Northwestern University Feinberg School of Medicine, 676 N. St. Clair Street, Suite 2210, Chicago, IL, 60611, USA.
Chengyuan WuDepartment of Neurological Surgery, Thomas Jefferson University Hospitals, Philadelphia, PA, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The transition to performing procedures robotically generally entails a period of adjustment known as a learning curve as the surgeon develops a familiarity with the technology. However, no study has comprehensively examined robotic learning curves across the field of neurosurgery. We conducted a systematic review to characterize the scope of literature on robotic learning curves in neurosurgery, assess operative parameters that may involve a learning curve, and delineate areas for future investigation. PubMed, Embase, and Scopus were searched. Following deduplication, articles were screened by title and abstract for relevance. Remaining articles were screened via full text for final inclusion. Bibliographic and learning curve data were extracted. Of 746 resultant articles, 32 articles describing 3074 patients were included, of which 23 (71.9%) examined spine, 4 (12.5%) pediatric, 4 (12.5%) functional, and 1 (3.1%) general neurosurgery. The parameters assessed for learning curves were heterogeneous. In total, 8 (57.1%) of 14 studies found reduced operative time with increased cases, while the remainder demonstrated no learning curve. Six (60.0%) of 10 studies reported reduced operative time per component with increased cases, while the remainder indicated no learning curve. Radiation time, radiation time per component, robot time, registration time, setup time, and radiation dose were assessed by ≤ 4 studies each, with 0-66.7% of studies demonstrated a learning curve. Four (44.4%) of 9 studies on accuracy showed improvement over time, while the others indicated no improvement over time. The number of cases required to reverse the learning curve ranged from 3 to 75. Learning curves are common in robotic neurosurgery. However, existing studies demonstrate high heterogeneity in assessed parameters and the number of cases that comprise the learning curve. Future studies should seek to develop strategies to reduce the number of cases required to reach the learning curve.

Indexed as

NeurosurgerySurgeonsChildHumansNeurosurgical ProceduresOperative TimeSpineArtificial intelligenceMachine learningNeurological surgerySpine surgeryStereotactic electroencephalography

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.