Safety profile and long-term efficacy of very high-power short-duration (60-70 W) catheter ablation for atrial fibrillation: results of a large comparative analysis.

Miruna A Popa, Felix Bourier, Sarah Lengauer, Hannah Krafft, Fabian Bahlke, Leonie V Förschner, Stephan Dorfmeister, Susanne Kathan, Marta Telishevska, Florian Englert and 5 more

Open access · hybridAbstract read
In one paragraph

Article in Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed, 1 pooled it
4.4field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 1 synthesis or guideline pooled it, 27 citations in OpenAlex.

  1. Pooled it
  2. Very high-power short-duration using 70W and a flexible tip ablation catheter for pulmonary vein isolation: the POWER PULSE randomized controlled trial.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2025
    Trial
  3. HIgh Power short duration radiofrequency ablation or cryoballoon ablation for paroxysmal Atrial Fibrillation (HIPAF trial).Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2025
    Trial
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Observational
  11. Article
  12. Optimal interlesion distance for 90 and 50 watt radiofrequency applications with low ablation index values: experimental findings in a chronic ovine model.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2023
    Article
  13. Article
  14. Review
  15. Revisiting symptomatic pulmonary vein stenosis after high-power short-duration radiofrequency ablation in patients with atrial fibrillation.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2023
    Article
  16. Progress in atrial fibrillation ablation during 25 years of Europace journal.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2023
    Article
  17. Acute oesophageal safety and long-term follow-up of AI-guided high-power short-duration with 50 W for atrial fibrillation ablation.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2023
    Article
  18. Putting novel ablation technologies to the test.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors at 1 institution in 1 country.

Miruna A PopaGerman Heart Center Munich, Department of Electrophysiology, Lazarettstraße 36, 80636 Munich, Germany.ORCID 0000-0002-9308-2492
Felix BourierGerman Heart Center Munich, Department of Electrophysiology, Lazarettstraße 36, 80636 Munich, Germany.ORCID 0000-0003-4861-6595
Sarah LengauerGerman Heart Center Munich, Department of Electrophysiology, Lazarettstraße 36, 80636 Munich, Germany.
Hannah KrafftGerman Heart Center Munich, Department of Electrophysiology, Lazarettstraße 36, 80636 Munich, Germany.ORCID 0000-0002-1151-7545
Fabian BahlkeGerman Heart Center Munich, Department of Electrophysiology, Lazarettstraße 36, 80636 Munich, Germany.ORCID 0000-0002-6265-5403
Leonie V FörschnerGerman Heart Center Munich, Department of Electrophysiology, Lazarettstraße 36, 80636 Munich, Germany.
Stephan DorfmeisterGerman Heart Center Munich, Department of Electrophysiology, Lazarettstraße 36, 80636 Munich, Germany.
Susanne KathanGerman Heart Center Munich, Department of Electrophysiology, Lazarettstraße 36, 80636 Munich, Germany.
Marta TelishevskaGerman Heart Center Munich, Department of Electrophysiology, Lazarettstraße 36, 80636 Munich, Germany.
Florian EnglertGerman Heart Center Munich, Department of Electrophysiology, Lazarettstraße 36, 80636 Munich, Germany.ORCID 0000-0002-3014-4190
Carsten LennerzGerman Heart Center Munich, Department of Electrophysiology, Lazarettstraße 36, 80636 Munich, Germany.ORCID 0000-0002-1693-6474
Tilko ReentsGerman Heart Center Munich, Department of Electrophysiology, Lazarettstraße 36, 80636 Munich, Germany.ORCID 0000-0002-7427-0359
Gabriele HesslingGerman Heart Center Munich, Department of Electrophysiology, Lazarettstraße 36, 80636 Munich, Germany.
Isabel DeisenhoferGerman Heart Center Munich, Department of Electrophysiology, Lazarettstraße 36, 80636 Munich, Germany.ORCID 0000-0001-5826-6846
Marc KottmaierGerman Heart Center Munich, Department of Electrophysiology, Lazarettstraße 36, 80636 Munich, Germany.ORCID 0000-0002-7742-5598
Deutsches Herzzentrum München · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimsThis retrospective study sought to compare complication rates and efficacy of power-controlled very high-power short-duration (vHPSD) and conventional catheter ablation in a large cohort of patients with atrial fibrillation (AF). METHODS AND

resultsWe analyzed 1115 consecutive patients with AF (38.7% paroxysmal, 61.3% persistent) who received first-time catheter ablation at our centre from 2015 to 2021. Circumferential pulmonary vein isolation ± additional substrate ablation using an irrigated-tip catheter was performed with vHPSD (70 W/5-7 s or 60 W/7-10 s) in 574 patients and with conventional power (30-35 W/15-30 s) in 541 patients. Baseline characteristics were well-balanced between groups (mean age 65.1 ± 11.2 years, 63.4% male). The 30-day incidence of cardiac tamponade [2/574 (0.35%) vs. 1/541 (0.18%), P = 0.598], pericardial effusion ≥ 10 mm [2/574 (0.35%) vs. 1/541 (0.18%), P = 0.598] and transient ischaemic attack [1/574 (0.17%) vs. 2/541 (0.37%), P = 0.529] was not significantly different between vHPSD and conventional ablation. No stroke, atrio-esophageal fistula, cardiac arrest or death occurred. Procedure (122.2 ± 46.8 min vs. 155.0 ± 50.5 min, P < 0.001), radiofrequency (22.4 ± 19.3 min vs. 52.9 ± 22.0 min, P < 0.001), and fluoroscopy (8.1 ± 7.2 vs. 9.2 ± 7.4, P = 0.016) duration were significantly shorter in the vHPSD group. At 12 months follow-up, freedom of any atrial arrhythmia was 44.1% vs. 34.2% (P = 0.010) in persistent AF and 78.1% vs. 70.2% in paroxysmal AF (P = 0.068).

conclusionvHPSD ablation is as safe as conventional ablation and is associated with an improved long-term efficacy in persistent AF.

Indexed as

Atrial FibrillationCatheter AblationPulmonary VeinsAgedCathetersFemaleHumansMaleMiddle AgedRetrospective StudiesTreatment OutcomeAblation technologiesAtrial fibrillationCatheter ablationHigh-power short-durationProcedural safety