Evidence map›Paper›PMID 36503976›Full record

ArticleArchives of gynecology and obstetrics2023

Automated breast ultrasound (ABUS) for intraoperative margin control on surgical specimens in breast conserving surgery.

Maria Eleni Hatzipanagiotou, Deborah Huber, Elisa Thede, Alexander Scheiter, Miriam Fernandez-Pacheco, Madeleine Hetterich, Blanca Roca Ripoll, Olaf Ortmann, Stephan Seitz

Abstract read
PubMed Publisher
In one paragraph

Article in Archives of gynecology and obstetrics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.1field-weighted citation impact, top 58% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Maria Eleni HatzipanagiotouDepartment of Gynecology and Obstetrics, University Medical Centre Regensburg, Landshuterstrasse 65, 93053, Regensburg, Germany. mhatzipanagiotou@csj.de.ORCID 0000-0003-2831-4282
Deborah HuberDepartment of Gynecology and Obstetrics, University Medical Centre Regensburg, Landshuterstrasse 65, 93053, Regensburg, Germany.
Elisa ThedeDepartment of Gynecology and Obstetrics, University Medical Centre Regensburg, Landshuterstrasse 65, 93053, Regensburg, Germany.
Alexander ScheiterDepartment of Pathology, University Medical Centre Regensburg, 93053, Regensburg, Germany.
Miriam Fernandez-PachecoDepartment of Gynecology and Obstetrics, University Medical Centre Regensburg, Landshuterstrasse 65, 93053, Regensburg, Germany.
Madeleine HetterichDepartment of Gynecology and Obstetrics, University Medical Centre Regensburg, Landshuterstrasse 65, 93053, Regensburg, Germany.
Blanca Roca RipollDepartment of Gynecology and Obstetrics, University Medical Centre Regensburg, Landshuterstrasse 65, 93053, Regensburg, Germany.
Olaf OrtmannDepartment of Gynecology and Obstetrics, University Medical Centre Regensburg, Landshuterstrasse 65, 93053, Regensburg, Germany.
Stephan SeitzDepartment of Gynecology and Obstetrics, University Medical Centre Regensburg, Landshuterstrasse 65, 93053, Regensburg, Germany.
University Hospital Regensburg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeAs breast-conserving surgery (BCS) has become the standard for treatment of early breast cancer, the need for new technologies to improve intraoperative margin assessment has become clear. Close or positive margins during BCS lead to additional surgeries, treatment delay, additional stress for patients and increasing healthcare cost. Automated three-dimensional breast ultrasound (ABUS) systems are meant to overcome the shortcomings of hand-held ultrasound (HHUS). In this study, we investigate the feasibility of ABUS to conduct ultrasound on surgical specimens in breast conserving therapy.

methodsIn this monocentric, non-interventional study, specimens of 40 women were examined via ABUS. A construction with isotonic saline solution, gel pads and ABUS membranes was invented by our team to produce images of breast cancer specimens using ABUS. Evaluation of the ABUS images was carried out by two independent physicians trained on ABUS evaluation.

resultsABUS was conducted on 40 specimens. 90% of the generated images were of high quality. Measured tumor sizes with ABUS were bigger than measured tumor size with HHUS (mean tumor size 22.9 vs. 18.1 mm, CI 2.38-7.35, p < 0.05). The mean difference between the ABUS tumor size and the pathological tumor size was 1.8 mm (CI - 0.84-4.53, p = 0.17). The mean difference between the HHUS tumor size and the pathological tumor size was 3.2 mm (CI - 5.35 to - 1.03, p = 0.005).

conclusionABUS seems to be a suitable method to conduct specimen ultrasound. Further studies are required to evaluate the accuracy of ABUS for intraoperative margin assessment and possible implementation in clinical work routine.

Indexed as

BreastBreast NeoplasmsMastectomy, SegmentalFemaleHumansMargins of ExcisionSensitivity and SpecificityUltrasonography, MammaryBreast imagingBreast surgeryMargin controlSpecimen ultrasound

Identifiers

PMID36503976
OpenAlexW4311123291

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.