Evidence map›Paper›PMID 36503318›Full record

ArticleInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences2024

Validation of three-dimensional printed models of intracranial aneurysms.

Daniel E Mantilla, Riccardo Ferrara, Andrés F Ortiz, Daniela D Vera, Franck Nicoud, Vincent Costalat

Abstract readValidation Study
In one paragraph

Article in Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Angiography-like neurovascular training without radiation utilizing optical cameras and virtual roadmap imaging.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Daniel E MantillaInterventional Radiology Department, Fundación oftalmológica de Santander Clínica Ardila Lülle, Floridablanca, Colombia.ORCID 0000-0002-5727-3195
Riccardo FerraraRiDev, Montpellier, France.
Andrés F OrtizInterventional Radiology Department, Fundación oftalmológica de Santander Clínica Ardila Lülle, Floridablanca, Colombia.ORCID 0000-0002-2625-0230
Daniela D VeraPhysician. Radiology Department, Fundación oftalmológica de Santander, Clínica Ardila Lülle, Floridablanca, Colombia.ORCID 0000-0002-4901-7490
Franck NicoudInstitut Montpelliérain Alexander, Grothendieck, CNRS, Univ. Montpellier, Montpellier, France.
Vincent CostalatNeuroradiology, Hôpital Güi-de-Chauliac, CHU de Montpellier, Montpellier, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThree-dimensional (3D) printing has evolved for medical applications as it can produce customized 3D models of devices and implants that can improve patient care. In this study, we aimed to validate the geometrical accuracy of the 3D models of intracranial aneurysms printed using Stereolithography 3D printing technology. MATERIALS AND

methodsTo compare the unruptured intracranial aneurysm mesh between the five patients and 3D printed models, we opened the DICOM files in the Sim&Size® simulation software, selected the region of interest, and performed the threshold check. We juxtaposed the 3D reconstructions and manually rotated the images to get the same orientation when needed and measured deviations at different nodes of the patient and 3D printed model meshes.

resultsIn the first patient, 80% of the nodes were separated by <0.56 mm and 0.17 mm. In the second patient, the deviations were below 0.17 mm for 80% of the meshes' nodes. In the next three patients, the deviations were below 0.21, 0.23, and 0.11 mm for 80% of the meshes' nodes. Finally, the overall deviation was below 0.21 mm for 80% of the mesh nodes of the five aneurysms.

conclusions3D printed models of intracranial aneurysms are accurate, having surfaces that resemble that of patients' angiographies with an 80% cumulative deviation below 0.21 mm.

Indexed as