Evidence map›Paper›PMID 36502242›Full record

ArticleSensors (Basel, Switzerland)2022

Analysis and Correction of Measurement Error of Spherical Capacitive Sensor Caused by Assembly Error of the Inner Frame in the Aeronautical Optoelectronic Pod.

Tianxiang Ma, Shengqi Yang, Yongsen Xu, Dachuan Liu, Jinghua Hou, Yunqing Liu

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Tianxiang MaInformation and Communication Engineering, School of Electronic and Information Engineering, Changchun University of Science and Technology, Changchun 130022, China.
Shengqi YangKey Laboratory of Airborne Optical Imaging and Measurement, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.ORCID 0000-0002-6513-8794
Yongsen XuKey Laboratory of Airborne Optical Imaging and Measurement, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
Dachuan LiuJiuquan Satellite Launch Centre, Jiuquan 732750, China.ORCID 0000-0003-1262-135X
Jinghua HouJiuquan Satellite Launch Centre, Jiuquan 732750, China.
Yunqing LiuInformation and Communication Engineering, School of Electronic and Information Engineering, Changchun University of Science and Technology, Changchun 130022, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The ball joint is a multi-degree-of-freedom transmission pair, if it can replace the inner frame in the aviation photoelectric pod to carry the optical load, which will greatly simplify the system structure of the photoelectric pod and reduce the space occupied by the inner frame. However, installation errors in ball joint siting introduce nonlinear errors that are difficult to correct and two degree of freedom angular displacement of the ball joint is difficult to detect, which limits application in the precision control of two degrees of freedom systems. Studies of spherical capacitive sensors to date have not tested sensors for use in an inner frame stabilisation mechanism nor have they analysed the influence of installation error on sensor output. A two-axis angular experimental device was designed to measure the performance of a ball joint capacitive sensor in a frame stabilisation mechanism in an aeronautical optoelectronic pod, and a mathematical model to compensate for ball joint capacitive sensor installation error was created and tested. The experimental results show that the resolution of the capacitive sensor was 0.02° in the operating range ±4°, the repeatability factor was 0.86%, and the pulse response time was 39 μs. The designed capacitive sensor has a simple structure, high measurement accuracy, and strong robustness, and it can be integrated into ball joint applications in the frames of aeronautical photoelectric pods.

Indexed as

2-DOF angular displacement measurementfour-quadrant differential structureinstallation error compensationspherical capacitive angular sensor

Identifiers

PMID36502242
PMCPMC9738035

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390