ArticleSensors (Basel, Switzerland)2022
Adaptive Inertial Sensor-Based Step Length Estimation Model.
Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Pedestrian dead reckoning (PDR) using inertial sensors has paved the way for developing several approaches to step length estimation. In particular, emerging step length estimation models are readily available to be utilized on smartphones, yet they are seldom formulated considering the kinematics of the human body during walking in combination with measured step lengths. We present a new step length estimation model based on the acceleration magnitude and step frequency inputs herein. Spatial positions of anatomical landmarks on the human body during walking, tracked by an optical measurement system, were utilized in the derivation process. We evaluated the performance of the proposed model using our publicly available dataset that includes measurements collected for two types of walking modes, i.e., walking on a treadmill and rectangular-shaped test polygon. The proposed model achieved an overall mean absolute error (MAE) of 5.64 cm on the treadmill and an overall mean walked distance error of 4.55% on the test polygon, outperforming all the models selected for the comparison. The proposed model was also least affected by walking speed and is unaffected by smartphone orientation. Due to its promising results and favorable characteristics, it could present an appealing alternative for step length estimation in PDR-based approaches.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.