Evidence map›Paper›PMID 36502098›Full record

ArticleSensors (Basel, Switzerland)2022

Smartphone Pedometer Sensor Application for Evaluating Disease Activity and Predicting Comorbidities in Patients with Rheumatoid Arthritis: A Validation Study.

Stefan R Wagner, Rasmus R Gregersen, Line Henriksen, Ellen-Margrethe Hauge, Kresten K Keller

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Stefan R WagnerDepartment of Electrical and Computer Engineering, Aarhus University, 8200 Aarhus, Denmark.
Rasmus R GregersenDepartment of Electrical and Computer Engineering, Aarhus University, 8200 Aarhus, Denmark.
Line HenriksenDepartment of Electrical and Computer Engineering, Aarhus University, 8200 Aarhus, Denmark.
Ellen-Margrethe HaugeDepartment of Rheumatology, Aarhus University Hospital, 8200 Aarhus, Denmark.
Kresten K KellerDepartment of Rheumatology, Aarhus University Hospital, 8200 Aarhus, Denmark.ORCID 0000-0003-2474-3389

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Smartphone-based pedometer sensor telemedicine applications could be useful for measuring disease activity and predicting the risk of developing comorbidities, such as pulmonary or cardiovascular disease, in patients with rheumatoid arthritis (RA), but the sensors have not been validated in this patient population. The aim of this study was to validate step counting with an activity-tracking application running the inbuilt Android smartphone pedometer virtual sensor in patients with RA. Two Android-based smartphones were tested in a treadmill test-bed setup at six walking speeds and compared to manual step counting as the gold standard. Guided by a facilitator, the participants walked 100 steps at each test speed, from 2.5 km/h to 5 km/h, wearing both devices simultaneously in a stomach pouch. A computer automatically recorded both the manually observed and the sensor step count. The overall difference in device step counts versus the observed was 5.9% mean absolute percentage error. Highest mean error was at the 2.5 km/h speed tests, where the mean error of the two devices was 18.5%. Both speed and cadence were negatively correlated to the absolute percentage error, which indicates that the greater the speed and cadence, the lower the resulting step counting error rate. There was no correlation between clinical parameters and absolute percentage error. In conclusion, the activity-tracking application using the inbuilt Android smartphone pedometer virtual sensor is valid for step counting in patients with RA. However, walking at very low speed and cadence may represent a challenge.

Indexed as

Arthritis, RheumatoidMobile ApplicationsActigraphyHumansSmartphoneWalkingWalking Speedactivity trackercomorbiditypedometerrheumatoid arthritissmartphone

Identifiers

PMID36502098
PMCPMC9735816

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.