Evidence map›Paper›PMID 36502050›Full record

ArticleSensors (Basel, Switzerland)2022

Self-Calibration of a Large-Scale Variable-Line-Spacing Grating for an Absolute Optical Encoder by Differencing Spatially Shifted Phase Maps from a Fizeau Interferometer.

Xin Xiong, Chenguang Yin, Lue Quan, Ryo Sato, Hiraku Matsukuma, Yuki Shimizu, Hideaki Tamiya, Wei Gao

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Review
  3. Feature Papers in Optical Sensors 2022.Sensors (Basel, Switzerland) · 2023
    Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Xin XiongDepartment of Finemechanics, Tohoku University, Sendai 980-8579, Japan.
Chenguang YinDepartment of Finemechanics, Tohoku University, Sendai 980-8579, Japan.ORCID 0000-0002-9536-6309
Lue QuanDepartment of Finemechanics, Tohoku University, Sendai 980-8579, Japan.
Ryo SatoDepartment of Finemechanics, Tohoku University, Sendai 980-8579, Japan.
Hiraku MatsukumaDepartment of Finemechanics, Tohoku University, Sendai 980-8579, Japan.
Yuki ShimizuDepartment of Human Mechanical Systems and Design, Hokkaido University, Sapporo 060-0808, Japan.ORCID 0000-0003-3527-2869
Hideaki TamiyaMagnescale Co., Ltd., Suzukawa 45, Isehara 259-1146, Japan.
Wei GaoDepartment of Finemechanics, Tohoku University, Sendai 980-8579, Japan.

Funding

Japan Society for the Promotion of Science 20H00211
6 · The paper itself

Abstract

A new method based on the interferometric pseudo-lateral-shearing method is proposed to evaluate the pitch variation of a large-scale planar variable-line-spacing (VLS) grating. In the method, wavefronts of the first-order diffracted beams from a planar VLS grating are measured by a commercial Fizeau form interferometer. By utilizing the differential wavefront of the first-order diffracted beam before and after the small lateral shift of the VLS grating, the pitch variation of the VLS grating can be evaluated. Meanwhile, additional positioning errors of the grating in the lateral shifting process could degrade the measurement accuracy of the pitch variation. To address the issue, the technique referred to as the reference plane technique is also introduced, where the least squares planes in the wavefronts of the first-order diffracted beams are employed to reduce the influences of the additional positioning errors of the VLS grating. The proposed method can also reduce the influence of the out-of-flatness of the reference flat in the Fizeau interferometer by taking the difference between the measured positive and negative diffracted wavefronts; namely, self-calibration can be accomplished. After the theoretical analysis and simulations, experiments are carried out with a large-scale VLS grating to verify the feasibility of the proposed methods. Furthermore, the evaluated VLS parameters are verified by comparing them with the readout signal of an absolute surface encoder employing the evaluated VLS grating as the scale for measurement.

Indexed as

InterferometryCalibrationdiffraction gratingsinterferometric pseudo-lateral-shearing methodinterferometryoptical encoderself-calibrationvariable-line-spacing grating

Identifiers

PMID36502050
PMCPMC9736133

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.