Evidence map›Paper›PMID 36501987›Full record

ArticleSensors (Basel, Switzerland)2022

Novel Vision Monitoring Method Based on Multi Light Points for Space-Time Analysis of Overhead Contact Line Displacements.

Andrzej Wilk, Len Gelman, Jacek Skibicki, Slawomir Judek, Krzysztof Karwowski, Aleksander Jakubowski, Paweł Kaczmarek

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Andrzej WilkFaculty of Electrical and Control Engineering, Gdańsk University of Technology, Narutowicza 11/12, 80-233 Gdańsk, Poland.
Len GelmanDepartment of Engineering and Technology, School of Computing and Engineering, University of Huddersfield, Queensgate, Huddersfield HD1 3DH, UK.
Jacek SkibickiFaculty of Electrical and Control Engineering, Gdańsk University of Technology, Narutowicza 11/12, 80-233 Gdańsk, Poland.ORCID 0000-0003-1373-0961
Slawomir JudekFaculty of Electrical and Control Engineering, Gdańsk University of Technology, Narutowicza 11/12, 80-233 Gdańsk, Poland.ORCID 0000-0003-4620-8416
Krzysztof KarwowskiFaculty of Electrical and Control Engineering, Gdańsk University of Technology, Narutowicza 11/12, 80-233 Gdańsk, Poland.ORCID 0000-0003-1662-6051
Aleksander JakubowskiFaculty of Electrical and Control Engineering, Gdańsk University of Technology, Narutowicza 11/12, 80-233 Gdańsk, Poland.ORCID 0000-0003-1532-5257
Paweł KaczmarekFaculty of Electrical and Control Engineering, Gdańsk University of Technology, Narutowicza 11/12, 80-233 Gdańsk, Poland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The article presents an innovative vision monitoring method of overhead contact line (OCL) displacement, which utilizes a set of LED light points installed along it. A light point is an, LED fed from a battery. Displacements of the LED points, recorded by a camera, are interpreted as a change of OCL shape in time and space. The vision system comprises a camera, properly situated with respect to the OCL, which is capable of capturing a dozen light points in its field of view. The monitoring system can be scaled by increasing the number of LED points and video cameras; thus, this method can be used for monitoring the motion of other large-size objects (e.g., several hundred meters). The applied method has made it possible to obtain the following novel results: vibration damping in a contact wire is nonlinear by nature and its intensity depends on the wire vibration amplitude; the natural frequency of contact wire vibration varies, and it is a function of vibration amplitude; the natural frequency of contact wire vibration also depends on the wire temperature. The proposed method can be used to monitor the uplift of contact and messenger wires in laboratory conditions, or for experimental OCL testing, as well as for verifying simulation models of OCL.

Indexed as

electric tractionimage processingoverhead contact line vibrationvision measurements

Identifiers

PMID36501987
PMCPMC9739504

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.