Evidence map›Paper›PMID 36501882›Full record

ArticleSensors (Basel, Switzerland)2022

Analysis of the Influence of the Geometrical Parameters of the Body Scanner on the Accuracy of Reconstruction of the Human Figure Using the Photogrammetry Technique.

Maciej Trojnacki, Przemysław Dąbek, Piotr Jaroszek

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Maciej TrojnackiEDUROCO sp. z o.o., ul. Łąkowa 3/5, 90-562 Łódź, Poland.ORCID 0000-0002-0394-2015
Przemysław DąbekŁUKASIEWICZ Research Network-Industrial Research Institute for Automation and Measurements PIAP, Al. Jerozolimskie 202, 02-486 Warsaw, Poland.
Piotr JaroszekEDUROCO sp. z o.o., ul. Łąkowa 3/5, 90-562 Łódź, Poland.

Funding

European Regional Development Fund POIR.01.01.01-00-0861/18
6 · The paper itself

Abstract

This article concerns the research of the HUBO full-body scanner, which includes the analysis and selection of the scanner's geometrical parameters in order to obtain the highest possible accuracy of the reconstruction of a human figure. In the scanner version analyzed in this paper, smartphone cameras are used as sensors. In order to process the collected photos into a 3D model, the photogrammetry technique is applied. As part of the work, dependencies between the geometrical parameters of the scanner are derived, which allows to significantly reduce the number of degrees of freedom in the selection of its geometrical parameters. Based on these dependencies, a numerical analysis is carried out, as a result of which the initial values of the geometrical parameters are pre-selected and distribution of scanner cameras is visualized. As part of the experimental research, the influence of selected scanner parameters on the scanning accuracy is analyzed. For the experimental research, a specially prepared dummy was used instead of the participation of a real human, which allowed to ensure the constancy of the scanned object. The accuracy of the object reconstruction was assessed in relation to the reference 3D model obtained with a scanner of superior measurement uncertainty. On the basis of the conducted research, a method for the selection of the scanner's geometrical parameters was finally verified, leading to the arrangement of cameras around a human, which guarantees high accuracy of the reconstruction. Additionally, to quantify the results, the quality rates were used, taking into account not only the obtained measurement uncertainty of the scanner, but also the processing time and the resulting efficiency.

Indexed as

Human BodyImaging, Three-DimensionalHumansPhotogrammetry3D model3D scannerexperimental researchHUBO scannerhuman body scannerhuman figurenumerical analysisphotogrammetryscanning accuracy

Identifiers

PMID36501882
PMCPMC9739902

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.