Evidence map›Paper›PMID 36501831›Full record

ArticleSensors (Basel, Switzerland)2022

Fuzzy Control of Pressure in a Water Supply Network Based on Neural Network System Modeling and IoT Measurements.

José Vinicius Santos de Araújo, Juan Moises Mauricio Villanueva, Marcio Miranda Cordula, Altamar Alencar Cardoso, Heber Pimentel Gomes

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

José Vinicius Santos de AraújoRenewable and Alternatives Energies Center (CEAR), Electrical Engineering Department (DEE), Campus I, Federal University of Paraiba (UFPB), Joao Pessoa 58051-900, Brazil.
Juan Moises Mauricio VillanuevaRenewable and Alternatives Energies Center (CEAR), Electrical Engineering Department (DEE), Campus I, Federal University of Paraiba (UFPB), Joao Pessoa 58051-900, Brazil.ORCID 0000-0002-8760-9390
Marcio Miranda CordulaWater and Sewerage Company of Paraíba CAGEPA, Joao Pessoa 58015-901, Brazil.
Altamar Alencar CardosoWater and Sewerage Company of Paraíba CAGEPA, Joao Pessoa 58015-901, Brazil.
Heber Pimentel GomesTechnology Center (CT), Department of Civil and Environmental Engineering (DECA), Campus I, Federal University of Paraiba (UFPB), Joao Pessoa 58051-900, Brazil.ORCID 0000-0001-8374-1469

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

As hydroenergetic losses are inherent to water supply systems, they are a frequent issue which water utilities deal with every day. The control of network pressure is essential to reducing these losses, providing a quality supply to consumers, saving electricity and preserving piping from excess pressure. However, to obtain these benefits, it is necessary to overcome some difficulties such as sensing the pressure of geographically distant consumer units and developing a control logic that is capable of making use of the data from these sensors and, at the same time, a good solution in terms of cost benefit. Therefore, this work has the purpose of developing a pressure monitoring and control system for water supply networks, using the ESP8266 microcontroller to collect data from pressure sensors for the integrated ScadaLTS supervisory system via the REST API. The modeling of the plant was developed using artificial neural networks together with fuzzy pressure control, both designed using the Python language. The proposed method was tested by considering a pumping station and two reference units located in the city of João Pessoa, Brazil, in which there was an excess of pressure in the supply network and low performance from the old controls, during the night period from 12:00 a.m. to 6:00 a.m. The field results estimated 2.9% energy saving in relation to the previous form of control and a guarantee that the pressure in the network was at a healthy level.

Indexed as

Fuzzy LogicWater SupplyCitiesNeural Networks, ComputerWaterWatercontrol pressurefuzzy control systemIoT module ESP8266neural network modelsScada-LTS

Identifiers

PMID36501831
PMCPMC9741241

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.