Evidence map›Paper›PMID 36501819›Full record

ArticleSensors (Basel, Switzerland)2022

A Magnetic Sensor Based on the Nonlinear Effect of Co-Rich Amorphous Wire.

Dongfeng He

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Dongfeng HeNational Institute for Materials Science, 1-2-1 Sengen, Tsukuba 305-0047, Ibaraki, Japan.ORCID 0000-0001-5670-4419

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A DC voltage induced by a DC magnetic field was observed for a coil with a Co-rich amorphous wire (FeCoSiB) as the core when an AC current flowed through the coil. The coil was 40 turns wound around a FeCoSiB amorphous wire with a diameter of 0.1 mm and a length of 8 mm. The magnitude of the DC voltage was determined by the frequency of the AC current, the amplitude of the AC current, and the applied DC magnetic field. When the sine wave current was 78 mA and the frequency was 6.8 MHz, a peak value of about 90 mV/Gauss DC voltage was observed. This phenomenon might have a relationship with the nonlinearity of the coil with the FeCoSiB amorphous wire as the core. A magnetic sensor with only an amplifier and a low-pass filter was developed using this effect.

Indexed as

amorphous wireFeCoSiBinductive coilmagnetic sensor

Identifiers

PMID36501819
PMCPMC9735912

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.