Evidence map›Paper›PMID 36501807›Full record

ArticleSensors (Basel, Switzerland)2022

Towards an Efficient Method for Large-Scale Wi-SUN-Enabled AMI Network Planning.

Marcos Alberto Mochinski, Marina Luísa de Souza Carrasco Vieira, Mauricio Biczkowski, Ivan Jorge Chueiri, Edgar Jamhour, Voldi Costa Zambenedetti, Marcelo Eduardo Pellenz, Fabrício Enembreck

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Analysis of Wi-SUN FAN Network Formation Time.Sensors (Basel, Switzerland) · 2024
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Marcos Alberto MochinskiCentro de P&I em Sistemas Elétricos Inteligentes (CISEI) - Smart Grid Research Center, Escola Politécnica, Pontifícia Universidade Católica do Paraná (PUCPR), Curitiba 80215-901, Brazil.ORCID 0000-0002-7118-9993
Marina Luísa de Souza Carrasco VieiraCentro de P&I em Sistemas Elétricos Inteligentes (CISEI) - Smart Grid Research Center, Escola Politécnica, Pontifícia Universidade Católica do Paraná (PUCPR), Curitiba 80215-901, Brazil.ORCID 0000-0002-8033-7513
Mauricio BiczkowskiSSG - Superintendência de Smart Grid e Projetos Especiais, COPEL Distribuição, Curitiba 81200-240, Brazil.
Ivan Jorge ChueiriCentro de P&I em Sistemas Elétricos Inteligentes (CISEI) - Smart Grid Research Center, Escola Politécnica, Pontifícia Universidade Católica do Paraná (PUCPR), Curitiba 80215-901, Brazil.ORCID 0000-0002-7393-2787
Edgar JamhourCentro de P&I em Sistemas Elétricos Inteligentes (CISEI) - Smart Grid Research Center, Escola Politécnica, Pontifícia Universidade Católica do Paraná (PUCPR), Curitiba 80215-901, Brazil.ORCID 0000-0001-6049-4573
Voldi Costa ZambenedettiCentro de P&I em Sistemas Elétricos Inteligentes (CISEI) - Smart Grid Research Center, Escola Politécnica, Pontifícia Universidade Católica do Paraná (PUCPR), Curitiba 80215-901, Brazil.ORCID 0000-0001-7706-3892
Marcelo Eduardo PellenzCentro de P&I em Sistemas Elétricos Inteligentes (CISEI) - Smart Grid Research Center, Escola Politécnica, Pontifícia Universidade Católica do Paraná (PUCPR), Curitiba 80215-901, Brazil.ORCID 0000-0001-6108-6272
Fabrício EnembreckCentro de P&I em Sistemas Elétricos Inteligentes (CISEI) - Smart Grid Research Center, Escola Politécnica, Pontifícia Universidade Católica do Paraná (PUCPR), Curitiba 80215-901, Brazil.ORCID 0000-0002-1418-3245

Funding

Companhia Paranaense de Energia - COPEL PD-02866-0478/2017 project, regulated by ANEEL.
6 · The paper itself

Abstract

In a smart grid communication network, positioning key devices (routers and gateways) is an NP-Hard problem as the number of candidate topologies grows exponentially according to the number of poles and smart meters. The different terrain profiles impose distinct communication losses between a smart meter and a key device position. Additionally, the communication topology must consider the position of previously installed distribution automation devices (DAs) to support the power grid remote operation. We introduce the heuristic method AIDA (AI-driven AMI network planning with DA-based information and a link-specific propagation model) to evaluate the connectivity condition between the meters and key devices. It also uses the link-received power calculated for the edges of a Minimum Spanning Tree to propose a simplified multihop analysis. The AIDA method proposes a balance between complexity and efficiency, eliminating the need for empirical terrain characterization. Using a spanning tree to characterize the connectivity topology between meters and routers, we suggest a heuristic approach capable of alleviating complexity and facilitating scalability. In our research, the interest is in proposing a method for positioning communication devices that presents a good trade-off between network coverage and the number of communication devices. The existing literature explores the theme by presenting different techniques for ideal device placement. Still rare are the references that meticulously explore real large-scale scenarios or the communication feasibility between meters and key devices, considering the detailed topography between the devices. The main contributions of this work include: (1) The presentation of an efficient AMI planning method with a large-scale focus; (2) The use of a propagation model that does not depend on an empirical terrain classification; and (3) The use of a heuristic approach based on a spanning tree, capable of evaluating a smaller number of connections and, even so, proposing a topology that uses fewer router and gateway positions compared to an approach that makes general terrain classification. Experiments in four real large-scale scenarios, totaling over 230,000 smart meters, demonstrate that AIDA can efficiently provide high-quality connectivity demanding a reduced number of devices. Additional experiments comparing AIDA's detailed terrain-based propagation model to the Erceg-SUI Path Loss model suggest that AIDA can reach the smart meter's coverage with a fewer router positions.

Indexed as

ElectricityAMI network planningkey device positioningsmart grid communication network

Identifiers

PMID36501807
PMCPMC9740512

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.