Evidence map›Paper›PMID 36499017›Full record

ArticleInternational journal of molecular sciences2022

Design and Validation of a Sensitive Multisteroid LC-MS/MS Assay for the Routine Clinical Use: One-Step Sample Preparation with Phospholipid Removal and Comparison to Immunoassays.

Valentin Braun, Hermann Stuppner, Lorenz Risch, Christoph Seger

Open access · goldAbstract read
In one paragraph

Article in International journal of molecular sciences, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.5field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Valentin BraunDepartment of Pharmacognosy, Institute of Pharmacy, Centrum of Chemistry and Biomedicine (CCB), University of Innsbruck, Innrain 80-82, A-6020 Innsbruck, Austria.ORCID 0000-0002-8991-0646
Hermann StuppnerDepartment of Pharmacognosy, Institute of Pharmacy, Centrum of Chemistry and Biomedicine (CCB), University of Innsbruck, Innrain 80-82, A-6020 Innsbruck, Austria.ORCID 0000-0001-8862-0201
Lorenz RischDr. Risch Ostschweiz AG, Lagerstrasse 30, 9470 Buchs, Switzerland.ORCID 0000-0003-2692-6699
Christoph SegerDepartment of Pharmacognosy, Institute of Pharmacy, Centrum of Chemistry and Biomedicine (CCB), University of Innsbruck, Innrain 80-82, A-6020 Innsbruck, Austria.ORCID 0000-0002-3984-461X
Universität Innsbruck · ATLabormedizinische Zentrum Dr Risch (Switzerland) · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Steroid analysis in clinical laboratories is dominated by immunoassays (IAs) that have a high sample turnover but are inherently limited in trueness, precision, and sensitivity. Liquid chromatography coupled to mass spectrometry (LC-MS/MS) has proved to be a far more capable tool, delivering better sensitivity, specificity, and the possibility of parallel analysis of multiple steroids and metabolites, providing the endocrinologist with more reliable and comprehensive diagnostic information. An LC-MS/MS assay with gradient elution over less than eight minutes and a one-step sample preparation combining protein precipitation with phospholipid removal of off-line solid-phase extraction was developed and validated. It allowed the quantification of 11-deoxycorticosterone (11-DOC), 11-deoxycortisol (11-DF), 17-OH-progesterone (17P), 21-deoxycortisol (21-DF), androstenedione (ANDRO), aldosterone (ALDO), corticosterone (CC), cortisol (CL), cortisone (CN), dehydroepiandrosterone (DHEA), dehydroepiandrosterone sulfate (DHEAS), dihydrotestosterone (DHT), estradiol (E2), progesterone (PROG), and testosterone (TES) in human serum. Interday imprecision was generally better than 15%, trueness was proven by recovery experiments with ISO 17034-certified reference materials, proficiency testing (UK NEQAS), and measuring serum reference standards. In-house comparison against IVD-CE-certified immunoassays (IA) for 17P, ANDRO, CL, DHEAS, E2, PROG, and TES was conducted by assessing leftover routine patient samples and purpose-built patient serum pools. None of the compared routine IAs were meeting the standards of the LC-MS/MS. Insufficient overall comparability was found for ANDRO and 17P (mean bias > +65%). Accuracy limitations at lower concentrations were present in IAs for PROG, E2, and TES.

Indexed as

ProgesteroneTandem Mass SpectrometryAndrostenedioneChromatography, LiquidHumansPhospholipidsSteroidsTestosteroneAndrostenedionePhospholipidsProgesteroneSteroidsTestosteroneendocrinologylaboratory medicineLC-MS/MSsteroid measurement

Identifiers

PMID36499017
PMCPMC9736865
OpenAlexW4310025030

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.