Measurements of Anterior and Posterior Corneal Curvatures with OCT and Scheimpflug Biometers in Patients with Low Total Corneal Astigmatism.
Article in Journal of clinical medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Upper Eyelid Blepharoplasty: Surgical Techniques and Results-Systematic Review and Meta-analysis.Aesthetic plastic surgery · 2023Pooled it
- Ocular biometry agreement among ZW-30, IOLMaster 700, and sirius in cataract patients.Scientific reports · 2026Article
- Comparing Refractive Prediction Accuracy of IOL Master 700 and Sirius Utilizing the Barrett Universal II Formula.Clinical ophthalmology (Auckland, N.Z.) · 2026Article
- The Effect of Tear Film Stability on Variability of Posterior Corneal Curvature Readings with a Swept-Source Optical Biometer in Cataract Patients.Clinical ophthalmology (Auckland, N.Z.) · 2026Article
- Assessing the interchangeability of keratometry measurements from four biometric devices in intraocular lens power calculations: insights into the predictive accuracy of five modern IOL formulas.BMC ophthalmology · 2025Article
- Anterior Segment Swept-Source Optical Coherence Tomography-based Assessment of Corneal Refractive Profiles in Stevens-Johnson Syndrome/Toxic Epidermal Necrolysis Patients: A Controlled Comparative Study.Korean journal of ophthalmology : KJO · 2025Article
- Accuracy of Toric Intraocular Lens Calculators with Predicted and Measured Posterior Corneal Astigmatism Across Different Types of Astigmatism.Ophthalmology and therapy · 2024Article
- Repeatability and Interobserver Reproducibility of a Swept-Source Optical Coherence Tomography for Measurements of Anterior, Posterior, and Total Corneal Power.Ophthalmology and therapy · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Posterior keratometry measurements are evolving features of the optical biometers. The differences between devices have bigger impact for the low astigmatism values. The majority of adults present the corneal astigmatism below 1.5 D. Objectives: To compare the total corneal astigmatism measured with two different technologies in cataract patients with corneal astigmatism below 1.5 D. Material and Methods: Three automated exams were performed on each of the two devices: swept-source optical coherence tomography (SS-OCT) and Scheimpflug biometers. The anterior and total corneal astigmatism and power were analysed. Statistical comparisons were performed for within-subject standard deviation, repeatability, Bland−Altman and vector analysis. Results: Twenty-nine eyes of twenty-seven patients were included. The limits of agreement between anterior and total corneal astigmatism were narrower for the SS-OCT than for the Scheimpflug biometer (−0.16 to 0.29 D and −0.40 to 0.39 D, respectively). The >0.5 D difference between SS-OCT and Scheimpflug total astigmatism was noticed in 5 (17%) of cases. The difference between mean total keratometric power for both devices was statistically significant (0.2 D, p < 0.001). SS-OCT total corneal flat measurements had worse repeatability than Scheimpflug (p = 0.007). Conclusions: For the corneal astigmatism <1.5 D, the difference between anterior and total corneal astigmatism measured with SS-OCT was clinically not significant. The mean anterior and total keratometry values obtained with Scheimpflug and SS-OCT biometers are not interchangeable.