ArticleInternational journal of environmental research and public health2022
Validation of Two Screening Tools for Detecting Delirium in Older Patients in the Post-Anaesthetic Care Unit: A Diagnostic Test Accuracy Study.
Article in International journal of environmental research and public health, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 5 citations in OpenAlex.
- Closing the gap in postoperative delirium detection: addressing low screening rates in the surgical recovery room.BMJ open quality · 2026Article
- Translation, Cultural Adaptation, and Validation of the Greek Version of the 4 'A's Test for Delirium Screening in Elderly Patients with Hip Fracture.Clinics and practice · 2026Article
- Approaches to Preoperative Assessment of Elderly Patients Undergoing Dental Surgical Interventions: A Systematic Review.Journal of clinical and experimental dentistry · 2026Review
- Sleep duration, depressive symptoms, and postoperative delirium: a mediation analysis.Frontiers in psychiatry · 2026Article
- A nomogram and risk stratification for predicting subsyndromal delirium in elderly patients in a post-anaesthesia care unit: A prospective cohort study.International journal of nursing studies advances · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
(1) Background: Delirium is a common complication among surgical patients after major surgery, but it is often underdiagnosed in the post-anaesthetic care unit (PACU). Valid and reliable tools are required for improving diagnoses of delirium. The objective of this study was to evaluate the diagnostic test accuracy of the Three-Minute Diagnostic Interview for Confusion Assessment Method (3D-CAM) and the 4A's Test (4AT) as screening tools for detection of delirium in older people in the PACU. (2) Methods: A prospective diagnostic test accuracy study was conducted in the PACU and surgical wards of a university-affiliated tertiary care hospital in Victoria, Australia. A consecutive prospective cohort of elective and emergency patients (aged 65 years or older) admitted to the PACU were recruited between July 2021 and December 2021 following a surgical procedure performed under general anaesthesia and expected to stay in the hospital for at least 24 h following surgery. The outcome measures were sensitivity, specificity positive predictive value and negative predictive value for 3D-CAM and 4AT. (3) Results: A total of 271 patients were recruited: 16.2% (44/271) had definite delirium. For a diagnosis of definite delirium, the 3D-CAM (area under curve (AUC) = 0.96) had a sensitivity of 100% (95% CI 92.0 to 100.0) in the PACU and during the first 5 days post-operatively. Specificity ranged from 93% (95% CI 87.8 to 95.2) to 91% (95% CI 85.9 to 95.2) in the PACU and during the first 5 days post-operatively. The 4AT (AUC = 0.92) had a sensitivity of 93% (95% CI 81.7 to 98.6) in the PACU and during the first 5 days post-operatively, and specificity ranged from 89% (95% CI 84.6 to 93.1) to 87% (95%CI 80.9 to 91.8) in the PACU and during the first 5 days post-operatively. (4) Conclusions: The 3D-CAM and the 4AT are sensitive and specific screening tools that can be used to detect delirium in older people in the PACU. Screening with either tool could have an important clinical impact by improving the accuracy of delirium detection in the PACU and hence preventing adverse outcomes associated with delirium.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.