Evidence map›Paper›PMID 36498093›Full record

ArticleInternational journal of environmental research and public health2022

Validation of Two Screening Tools for Detecting Delirium in Older Patients in the Post-Anaesthetic Care Unit: A Diagnostic Test Accuracy Study.

Rami K Aldwikat, Elizabeth Manias, Alex Holmes, Emily Tomlinson, Patricia Nicholson

Open access · goldAbstract read
In one paragraph

Article in International journal of environmental research and public health, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.5field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Rami K AldwikatSchool of Nursing and Midwifery, Deakin University, Geelong, VIC 3220, Australia.ORCID 0000-0003-2886-5180
Elizabeth ManiasSchool of Nursing and Midwifery, Faculty of Medicine, Nursing and Health Sciences, Monash University, Clayton, VIC 3800, Australia.ORCID 0000-0002-3747-0087
Alex HolmesDepartment of Psychiatry, The University of Melbourne, Parkville, VIC 3010, Australia.
Emily TomlinsonSchool of Nursing and Midwifery, Deakin University, Geelong, VIC 3220, Australia.
Patricia NicholsonSchool of Nursing and Midwifery, Deakin University, Geelong, VIC 3220, Australia.ORCID 0000-0002-7802-6863
The Royal Melbourne Hospital · AUDeakin University · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

(1) Background: Delirium is a common complication among surgical patients after major surgery, but it is often underdiagnosed in the post-anaesthetic care unit (PACU). Valid and reliable tools are required for improving diagnoses of delirium. The objective of this study was to evaluate the diagnostic test accuracy of the Three-Minute Diagnostic Interview for Confusion Assessment Method (3D-CAM) and the 4A's Test (4AT) as screening tools for detection of delirium in older people in the PACU. (2) Methods: A prospective diagnostic test accuracy study was conducted in the PACU and surgical wards of a university-affiliated tertiary care hospital in Victoria, Australia. A consecutive prospective cohort of elective and emergency patients (aged 65 years or older) admitted to the PACU were recruited between July 2021 and December 2021 following a surgical procedure performed under general anaesthesia and expected to stay in the hospital for at least 24 h following surgery. The outcome measures were sensitivity, specificity positive predictive value and negative predictive value for 3D-CAM and 4AT. (3) Results: A total of 271 patients were recruited: 16.2% (44/271) had definite delirium. For a diagnosis of definite delirium, the 3D-CAM (area under curve (AUC) = 0.96) had a sensitivity of 100% (95% CI 92.0 to 100.0) in the PACU and during the first 5 days post-operatively. Specificity ranged from 93% (95% CI 87.8 to 95.2) to 91% (95% CI 85.9 to 95.2) in the PACU and during the first 5 days post-operatively. The 4AT (AUC = 0.92) had a sensitivity of 93% (95% CI 81.7 to 98.6) in the PACU and during the first 5 days post-operatively, and specificity ranged from 89% (95% CI 84.6 to 93.1) to 87% (95%CI 80.9 to 91.8) in the PACU and during the first 5 days post-operatively. (4) Conclusions: The 3D-CAM and the 4AT are sensitive and specific screening tools that can be used to detect delirium in older people in the PACU. Screening with either tool could have an important clinical impact by improving the accuracy of delirium detection in the PACU and hence preventing adverse outcomes associated with delirium.

Indexed as

DeliriumAgedDiagnostic Tests, RoutineHumansProspective StudiesSensitivity and SpecificityVictoriadeliriumdiagnostic accuracyolder peoplepost-anaesthetic care unitscreening tools

Identifiers

PMID36498093
PMCPMC9738308
OpenAlexW4311012110

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked