Evidence map›Paper›PMID 36494470›Full record

ArticleScientific reports2022

Cycloidal-spiral sampling for three-modal x-ray CT flyscans with two-dimensional phase sensitivity.

G Lioliou, O Roche I Morgó, S Marathe, K Wanelik, S Cipiccia, A Olivo, C K Hagen

Abstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

G LioliouDepartment of Medical Physics and Biomedical Engineering, University College London, Malet Place, London, WC1E 6BT, UK. g.lioliou@ucl.ac.uk.
O Roche I MorgóDepartment of Medical Physics and Biomedical Engineering, University College London, Malet Place, London, WC1E 6BT, UK.
S MaratheDiamond Light Source, Harwell Science and Innovation Campus, Fermi Avenue, Didcot, OX11 0DE, UK.
K WanelikDiamond Light Source, Harwell Science and Innovation Campus, Fermi Avenue, Didcot, OX11 0DE, UK.
S CipicciaDepartment of Medical Physics and Biomedical Engineering, University College London, Malet Place, London, WC1E 6BT, UK.
A OlivoDepartment of Medical Physics and Biomedical Engineering, University College London, Malet Place, London, WC1E 6BT, UK.
C K HagenDepartment of Medical Physics and Biomedical Engineering, University College London, Malet Place, London, WC1E 6BT, UK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We present a flyscan compatible acquisition scheme for three-modal X-Ray Computed Tomography (CT) with two-dimensional phase sensitivity. Our approach is demonstrated using a "beam tracking" setup, through which a sample's attenuation, phase (refraction) and scattering properties can be measured from a single frame, providing three complementary contrast channels. Up to now, such setups required the sample to be stepped at each rotation angle to sample signals at an adequate rate, to prevent resolution losses, anisotropic resolution, and under-sampling artefacts. However, the need for stepping necessitated a step-and-shoot implementation, which is affected by motors' overheads and increases the total scan time. By contrast, our proposed scheme, by which continuous horizontal and vertical translations of the sample are integrated with its rotation (leading to a "cycloidal-spiral" trajectory), is fully compatible with continuous scanning (flyscans). This leads to greatly reduced scan times while largely preserving image quality and isotropic resolution.

Indexed as

AlgorithmsTomography, X-Ray ComputedArtifactsPhantoms, ImagingX-Rays

Identifiers

PMID36494470
PMCPMC9734192

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.