Evidence map›Paper›PMID 36484886›Full record

ReviewVisual computing for industry, biomedicine, and art2022

Cardiac CT blooming artifacts: clinical significance, root causes and potential solutions.

Jed D Pack, Mufeng Xu, Ge Wang, Lohendran Baskaran, James Min, Bruno De Man

Open access · diamondAbstract readReview
In one paragraph

Review in Visual computing for industry, biomedicine, and art, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 46 papers.

0numbers the graph read from it
0cells of the map it votes in
46citing papers in PubMed
5.1field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

46 citing papers in PubMed, 68 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

Jed D PackGE Research, Niskayuna, NY, 12309, USA.
Mufeng XuRensselaer Polytechnic Institute, Troy, NY 12180, USA.
Ge WangRensselaer Polytechnic Institute, Troy, NY 12180, USA.
Lohendran BaskaranWeill Cornell Medicine, New York, NY 10065, USA.
James MinWeill Cornell Medicine, New York, NY 10065, USA.
Bruno De ManGE Research, Niskayuna, NY, 12309, USA. deman@ge.com.ORCID http://orcid.org/0000-0001-7250-3406
Cornell University · USGE Global Research (United States) · USRensselaer Polytechnic Institute · US

Funding

Cardiac CT DebloomingR01HL151561 · NHLBI · GENERAL ELECTRIC GLOBAL RESEARCH CTR · PI BUDOFF, MATTHEW J, DE MAN, BRUNO · 2020 to 2023
$3.8M
NHLBI NIH HHS R01 HL151561
6 · The paper itself

Abstract

This review paper aims to summarize cardiac CT blooming artifacts, how they present clinically and what their root causes and potential solutions are. A literature survey was performed covering any publications with a specific interest in calcium blooming and stent blooming in cardiac CT. The claims from literature are compared and interpreted, aiming at narrowing down the root causes and most promising solutions for blooming artifacts. More than 30 journal publications were identified with specific relevance to blooming artifacts. The main reported causes of blooming artifacts are the partial volume effect, motion artifacts and beam hardening. The proposed solutions are classified as high-resolution CT hardware, high-resolution CT reconstruction, subtraction techniques and post-processing techniques, with a special emphasis on deep learning (DL) techniques. The partial volume effect is the leading cause of blooming artifacts. The partial volume effect can be minimized by increasing the CT spatial resolution through higher-resolution CT hardware or advanced high-resolution CT reconstruction. In addition, DL techniques have shown great promise to correct for blooming artifacts. A combination of these techniques could avoid repeat scans for subtraction techniques.

Indexed as

Beam hardeningCalcium bloomingCardiac CTCoronary artery imagingIn-stent restenosisMotion artifactsPartial volume

Identifiers

PMID36484886
PMCPMC9733770
OpenAlexW4311205854

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.