Evidence map›Paper›PMID 36484766›Full record

ArticleLab on a chip2022

Multiplexed fluidic circuit board for controlled perfusion of 3D blood vessels-on-a-chip.

Mees N S de Graaf, Aisen Vivas, Dhanesh G Kasi, Francijna E van den Hil, Albert van den Berg, Andries D van der Meer, Christine L Mummery, Valeria V Orlova

Open access · hybridAbstract read
In one paragraph

Article in Lab on a chip, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
1.5field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 21 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Review
  6. Article
  7. Review
  8. Article
  9. Acoustofluidic Engineering of Functional Vessel-on-a-Chip.ACS biomaterials science & engineering · 2023
    Article
  10. Review
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Mees N S de GraafDepartment of Anatomy and Embryology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands. v.orlova@lumc.nl.ORCID 0000-0001-7823-9941
Aisen VivasApplied Stem Cell Technologies, University of Twente, 7500AE Enschede, The Netherlands.ORCID 0000-0003-1721-8682
Dhanesh G KasiDepartment of Anatomy and Embryology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands. v.orlova@lumc.nl.
Francijna E van den HilDepartment of Anatomy and Embryology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands. v.orlova@lumc.nl.
Albert van den BergBIOS Lab on a Chip Group, MESA+ Institute for Nanotechnology, Technical Medical Centre, Max Planck Institute for Complex Fluid Dynamics, University of Twente, 7500AE Enschede, The Netherlands.ORCID 0000-0001-9019-933X
Andries D van der MeerApplied Stem Cell Technologies, University of Twente, 7500AE Enschede, The Netherlands.ORCID 0000-0002-8761-4077
Christine L MummeryDepartment of Anatomy and Embryology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands. v.orlova@lumc.nl.ORCID 0000-0002-4549-6535
Valeria V OrlovaDepartment of Anatomy and Embryology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands. v.orlova@lumc.nl.ORCID 0000-0002-1169-2802
Leiden University Medical Center · NLMax Planck University of Twente Center for Complex Fluid Dynamics · NLUniversity of Twente · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Three-dimensional (3D) blood vessels-on-a-chip (VoC) models integrate the biological complexity of vessel walls with dynamic microenvironmental cues, such as wall shear stress (WSS) and circumferential strain (CS). However, these parameters are difficult to control and are often poorly reproducible due to the high intrinsic diameter variation of individual 3D-VoCs. As a result, the throughput of current 3D systems is one-channel-at-a-time. Here, we developed a fluidic circuit board (FCB) for simultaneous perfusion of up to twelve 3D-VoCs using a single set of control parameters. By designing the internal hydraulic resistances in the FCB appropriately, it was possible to provide a pre-set WSS to all connected 3D-VoCs, despite significant variation in lumen diameters. Using this FCB, we found that variation of CS or WSS induce morphological changes to human induced pluripotent stem cell (hiPSC)-derived endothelial cells (ECs) and conclude that control of these parameters using a FCB is necessary to study 3D-VOCs.

Indexed as

Endothelial CellsInduced Pluripotent Stem CellsHumansLab-On-A-Chip DevicesPerfusionStress, Mechanical

Identifiers

PMID36484766
PMCPMC9764810
OpenAlexW4310968672

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.